R43HD116647↗
Pendar Technologies LLC received this grant or assistance award from National Institutes of Health: $318.7K obligated so far for child health and human development extramural research. Its latest action was on 2026-04-02.
Key facts · data as of Nov 5, 2026
- Recipient
- Pendar Technologies LLC
- Awarding agency
- National Institutes of Health (Department of Health and Human Services)
- Obligated to date
- $318.7K
Source: USAspending.gov prime award records (obligations: money committed, not outlays), data as of Nov 5, 2026.
Cite this page: SpendQuery, Award R43HD116647, data as of Nov 5, 2026, https://spendquery.com/award?id=ASST_NON_R43HD116647_075
Pendar Technologies LLC: all federal awards · Department of Health and Human Services: spending
MONITORING OF OXYGEN DELIVERY AND TISSUE OXYGENATION DEPRIVATION IN CRITICALLY ILL NEONATES USING RESONANCE RAMAN SPECTROSCOPY - SUMMARY/ABSTRACT SHOCK PHYSIOLOGY, FROM ANY CAUSE, IS CHARACTERIZED BY AN INABILITY TO DELIVER SUFFICIENT OXYGEN TO THE TISSUES TO MEET CELLULAR METABOLIC DEMANDS. UNFORTUNATELY, TOOLS THAT ASSESS THE ADEQUACY OF OXYGEN DELIVERY IN NEONATAL CRITICAL CARE PATIENTS ARE OFTEN INVASIVE, IMPRECISE, INTERMITTENT, AND MAY BE MISLEADING. FOR EXAMPLE, A PATIENT WITH SIGNIFICANT MICROVASCULAR SHUNTING MAY EXHIBIT A FALSELY REASSURING ARTERIAL OXYHEMOGLOBIN SATURATION OR NORMAL LACTIC ACID LEVELS. STILL, EARLY IDENTIFICATION OF THE SHOCK STATE IS CRITICAL TO THE APPROPRIATE TRIAGE, RESUSCITATION, AND TREATMENT OF PATIENTS. HERE, WE PROPOSE THE ADVANCED DEVELOPMENT AND TESTING OF AN OPTICAL PROBE THAT MONITORS PERIPHERAL TISSUE OXYGENATION AS A MARKER OF SYSTEMIC HEMODYNAMICS WITH STRONG CORRELATION TO CENTRAL VENOUS OXYGEN SATURATION. LOCAL, CAPILLARY-SHBO2 (CALLED STO2), PRIMARILY REFLECTS THE VENOUS OR POST-O2 EXTRACTION COMPARTMENT OF THE VASCULATURE AND, THUS, REFLECTS THE ADEQUACY OF OXYGEN DELIVERY TO TISSUES. CHANGES TO SYSTEMIC BLOOD SUPPLY, FOR EXAMPLE DUE TO BLEEDING, INFECTION, OR LOW CARDIAC OUTPUT MAY NOT CHANGE ARTERIAL OXYGEN SATURATION, BUT ARE QUICKLY REFLECTED IN PERIPHERAL STO2 AS TOTAL OXYGEN DELIVERY IS REDUCED OR PERIPHERAL CAPILLARIES ARE SHUNTED TO MAINTAIN SYSTEMIC PERFUSION. WE HAVE DEVELOPED A METHOD FOR MEASURING STO2 BASED ON RESONANCE RAMAN SPECTROSCOPY (RRS). RRS TAKES ADVANTAGE OF RESONANT ENHANCEMENT OF THE VIBRATIONAL SPECTRA FROM HEMOGLOBIN WHEN EXCITED USING A LOW POWER LASER NEAR A STRONG ABSORPTION PEAK (405NM). THUS, THE STO2 MEASUREMENT CAN BE TAKEN AGAINST A TISSUE BACKGROUND AND IS INSENSITIVE TO FACTORS SUCH AS SUBCUTANEOUS FAT AND SKIN COLOR. USING A PROTOTYPE DEVICE IN ANIMAL MODELS, WE HAVE DEMONSTRATED THE UTILITY AND FEASIBILITY OF MEASURING STO2 FROM THE ESOPHAGUS AS A PREDICTOR OF DECOMPENSATION DUE TO HEMORRHAGE. IN ADDITION, WE CONFIRMED THE SAFETY OF LONG TERM USE OF THE DEVICE. HERE, WE PROPOSE IMPROVEMENTS TO OUR SENSOR WHICH WILL ENABLE MEASUREMENTS IN A WIDER RANGE OF TISSUES AND WILL PREPARE US TO BEGIN CLINICAL TRIALS IN A NEONATAL CRITICAL CARE PATIENT POPULATION.
What it is
- Program
- Child Health and Human Development Extramural Research (Assistance Listing 93.865)
- Where the work is
- MA
The research project
Monitoring of Oxygen Delivery and Tissue Oxygenation Deprivation in Critically Ill Neonates Using Resonance Raman Spectroscopy · Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD) · led by Daryoosh Vakhshoori and 1 more, PENDAR TECHNOLOGIES, LLC
“Shock physiology, from any cause, is characterized by an inability to deliver sufficient oxygen to the tissues to meet cellular metabolic demands. Unfortunately, tools that assess the adequacy of oxygen delivery in neonatal critical care patients are often invasive, imprecise, intermittent, and may be misleading.” Full abstract on RePORTER ↗
NIH research categories: Bioengineering · Pediatric
NIH funding by fiscal year: FY2024 $318.7K · project period 2024-09-01 to 2025-08-31.
Source: NIH RePORTER, project R43HD116647. RePORTER counts NIH's awards by year; USAspending's obligations above count each action.
Obligations by fiscal year
SpendQuery holds FY2023 on; earlier years are on USAspending.gov.
Subrecipients: where the money went next
No subawards reported for this award. Primes report subawards of $30,000 or more; many awards have none.
Every action
3 actions since 2024-08-28. Each is a modification or amendment with the money it added or took back.
| Date | Amendment | Kind | Amount | What the agency wrote |
|---|---|---|---|---|
| 2026-04-02 | 000 | Revision | $0 | MONITORING OF OXYGEN DELIVERY AND TISSUE OXYGENATION DEPRIVATION IN CRITICALLY ILL NEONATES USING RESONANCE RAMAN SPECTROSCOPY - SUMMARY/ABSTRACT SHOCK PHYSIOLOGY, FROM ANY CAUSE, IS CHARACTERIZED BY AN INABILITY TO DELIVER SUFFICIENT OXYGEN TO THE TISSUES… |
| 2024-09-23 | 001 | Revision | $0 | MONITORING OF OXYGEN DELIVERY AND TISSUE OXYGENATION DEPRIVATION IN CRITICALLY ILL NEONATES USING RESONANCE RAMAN SPECTROSCOPY - SUMMARY/ABSTRACT SHOCK PHYSIOLOGY, FROM ANY CAUSE, IS CHARACTERIZED BY AN INABILITY TO DELIVER SUFFICIENT OXYGEN TO THE TISSUES… |
| 2024-08-28 | 000 | New award | $318.7K | MONITORING OF OXYGEN DELIVERY AND TISSUE OXYGENATION DEPRIVATION IN CRITICALLY ILL NEONATES USING RESONANCE RAMAN SPECTROSCOPY - SUMMARY/ABSTRACT SHOCK PHYSIOLOGY, FROM ANY CAUSE, IS CHARACTERIZED BY AN INABILITY TO DELIVER SUFFICIENT OXYGEN TO THE TISSUES… |
Source: USAspending.gov prime award transactions and FSRS subaward reports, as loaded by SpendQuery (data as of 2026-11-05). Amounts are obligations (money committed), not outlays. The official record on USAspending.gov ↗