R44ES035665↗

Photothermal Spectroscopy Corp. received this grant or assistance award from National Institutes of Health: $1.02M obligated so far for environmental health. Its latest action was on 2026-08-13.

Key facts · data as of Nov 10, 2026

Recipient
Photothermal Spectroscopy Corp.
Awarding agency
National Institutes of Health (Department of Health and Human Services)
Obligated to date
$1.02M

Source: USAspending.gov prime award records (obligations: money committed, not outlays), data as of Nov 10, 2026.

Cite this page: SpendQuery, Award R44ES035665, data as of Nov 10, 2026, https://spendquery.com/award?id=ASST_NON_R44ES035665_075

HIGH-SPEED AUTOMATED ANALYSIS OF SUB-20 ΜM MICROPLASTICS BY PHOTOTHERMAL INFRARED SPECTROSCOPY - PROJECT SUMMARY/ABSTRACT MICROPLASTICS (MPS), DEFINED BY NIH AS PLASTIC WASTE PARTICLES RANGING FROM 0.1 ΜM TO 5 MM, ARE NOW UBIQUITOUS IN WATER, AIR, SOIL, AND FOOD, POSING SIGNIFICANT ENVIRONMENTAL AND HUMAN HEALTH RISKS. DESPITE GROWING CONCERNS, EXISTING TECHNIQUES STRUGGLE TO ANALYZE THE SMALLEST AND MOST HAZARDOUS PARTICLES, PARTICULARLY THOSE BELOW 20 ΜM. CURRENT FT-IR AND RAMAN SPECTROSCOPY TECHNIQUES ARE INSUFFICIENT DUE TO SPATIAL RESOLUTION LIMITS, SCATTERING ARTIFACTS, AND LENGTHY MEASUREMENT TIMES, MAKING THEM IMPRACTICAL FOR HIGH-THROUGHPUT ANALYSIS OF SUB-20 ΜM MPS, ESPECIALLY SUB-ΜM MPS. PHOTOTHERMAL SPECTROSCOPY CORP (PSC) PROPOSES TO DEVELOP AND COMMERCIALIZE THE PHOTOTHERMAL INFRARED PARTICLE ANALYZER (PIPA)—A HIGH-SPEED, AUTOMATED PLATFORM CAPABLE OF DETECTING, ANALYZING, AND REPORTING THE SIZE, SHAPE, AND CHEMICAL IDENTITY OF >1000 PARTICLES PER HOUR WITH SENSITIVITY DOWN TO <0.5 ΜM. PIPA LEVERAGES INNOVATIVE LASER-SCANNING OPTICAL PHOTOTHERMAL INFRARED (O-PTIR) MICROSCOPY, OFFERING ~20X BETTER SPATIAL RESOLUTION THAN CONVENTIONAL FT-IR AND LDIR SYSTEMS AND >10X FASTER IMAGING THAN CONVENTIONAL O-PTIR SYSTEMS. THE PROPOSED PIPA PLATFORM ADDRESSES CRITICAL LIMITATIONS IN CURRENT METHODS BY AUTOMATING PARTICLE SEGMENTATION, MULTI-SPECTRAL PRE-SCREENING TO ELIMINATE NON- PLASTICS, AND HIGH-SPEED SPECTRAL MEASUREMENT WITH ADVANCED CLASSIFICATION ALGORITHMS—DELIVERING A ~50X IMPROVEMENT IN OVERALL MEASUREMENT, ANALYSIS, AND REPORTING THROUGHPUT, WHILE CUTTING TOTAL LABOR FROM HOURS TO MINUTES PER DATASET. PSC’S O-PTIR TECHNOLOGY HAS ALREADY BEEN ADOPTED BY EARLY RESEARCHERS FOR MP ANALYSIS ACROSS DIVERSE MATRICES, INCLUDING AIR, WATER, FOOD, AND BIOLOGICAL TISSUES, DEMONSTRATING ITS POTENTIAL TO ADDRESS CURRENT ANALYTICAL GAPS. THE PIPA PLATFORM HAS ALSO GARNERED STRONG INTEREST AND SUPPORT FROM KEY STAKEHOLDERS IN MICROPLASTICS RESEARCH AND ENVIRONMENTAL TESTING, HIGHLIGHTING ITS POTENTIAL TO STANDARDIZE AND ACCELERATE MP ANALYSIS IN HIGH-IMPACT APPLICATIONS. PIPA’S HIGH-THROUGHPUT CAPABILITIES WILL MEET THE GROWING DEMAND FOR MICROPLASTICS ANALYSIS ACROSS ENVIRONMENTAL, BIOMEDICAL, AND REGULATORY APPLICATIONS, PROVIDING A TRANSFORMATIVE SOLUTION FOR CHARACTERIZING MPS IN COMPLEX MATRICES. THIS PROJECT DIRECTLY RESPONDS TO THE NIH NOTICE OF SPECIAL INTEREST (NOT-ES-23-002) “UNDERSTANDING EXPOSURE AND HEALTH EFFECTS OF MICRO AND/OR NANOPLASTICS,” ESPECIALLY THE NEED TO “DEVELOP METHODS TO DETECT AND QUANTIFY MICROPLASTICS AND NANOPLASTICS IN ENVIRONMENTAL AND BIOLOGICAL SAMPLES.” BEYOND MICROPLASTICS, PIPA HAS THE POTENTIAL TO ADVANCE HIGH- THROUGHPUT ANALYSIS OF CELLULAR AND BACTERIAL POPULATIONS AND SUPPORT CRITICAL RESEARCH INITIATIVES IN ENVIRONMENTAL HEALTH AND TOXICOLOGY.

Project Grant (B) · National Institutes of Health · to Photothermal Spectroscopy Corp. (UEI EAKGDLLRU254) · data as of 2026-11-10

Obligated to date$1.02M1 action
Period2026-08-13 → 2026-08-13first to last action

What it is

Program
Environmental Health (Assistance Listing 93.113)
Where the work is
Santa Barbara, CA · district CA-24

The research project

High-Speed Automated Analysis of Sub-20 µm Microplastics by Photothermal Infrared Spectroscopy · National Institute of Environmental Health Sciences (NIEHS) · led by Kevin Kjoller, PHOTOTHERMAL SPECTROSCOPY CORP.

“Microplastics (MPs), defined by NIH as plastic waste particles ranging from 0.1 µm to 5 mm, are now ubiquitous in water, air, soil, and food, posing significant environmental and human health risks.” Full abstract on RePORTER ↗

NIH funding by fiscal year: FY2026 $1.02M · project period 2026-08-13 to 2028-07-31.

Source: NIH RePORTER, project R44ES035665. RePORTER counts NIH's awards by year; USAspending's obligations above count each action.

Obligations by fiscal year

FY2026$1.02M

SpendQuery holds FY2023 on; earlier years are on USAspending.gov.

Subrecipients: where the money went next

No subawards reported for this award. Primes report subawards of $30,000 or more; many awards have none.

Every action

1 action since 2026-08-13. Each is a modification or amendment with the money it added or took back.

DateAmendmentKindAmountWhat the agency wrote
2026-08-13000New award$1.02MHIGH-SPEED AUTOMATED ANALYSIS OF SUB-20 ΜM MICROPLASTICS BY PHOTOTHERMAL INFRARED SPECTROSCOPY - PROJECT SUMMARY/ABSTRACT MICROPLASTICS (MPS), DEFINED BY NIH AS PLASTIC WASTE PARTICLES RANGING FROM 0.1 ΜM TO 5 MM, ARE NOW UBIQUITOUS IN WATER, AIR, SOIL, AND…

Source: USAspending.gov prime award transactions and FSRS subaward reports, as loaded by SpendQuery (data as of 2026-11-10). Amounts are obligations (money committed), not outlays. The official record on USAspending.gov ↗