R44GM148148↗

Sigray, Inc. received this grant or assistance award from National Institutes of Health: $732.5K obligated so far for biomedical research and research training. Its latest action was on 2026-04-24.

Key facts · data as of Nov 5, 2026

Recipient
Sigray, Inc.
Awarding agency
National Institutes of Health (Department of Health and Human Services)
Obligated to date
$732.5K

Source: USAspending.gov prime award records (obligations: money committed, not outlays), data as of Nov 5, 2026.

Cite this page: SpendQuery, Award R44GM148148, data as of Nov 5, 2026, https://spendquery.com/award?id=ASST_NON_R44GM148148_075

CRYOGENIC HIGH-THROUGHPUT CELLULAR IMAGING SYSTEM - PROJECT SUMMARY/ABSTRACT X-RAY MICROSCOPY HAS EVOLVED INTO AN IMPORTANT ULTRASTRUCTURE IMAGING APPROACH FOR VISUALIZING AND MEASURING INTACT CELLS IN THREE DIMENSIONS. BEAMLINES DEDICATED TO CELLULAR IMAGING HAVE BEEN CONSTRUCTED AT SYNCHROTRON FACILITIES AROUND THE WORLD, AND THE CO-PI OF THIS PROPOSAL DEVELOPED THE FIRST COMMERCIAL LABORATORY X-RAY MICROSCOPE FOR CELLULAR IMAGING. THE APPROACHES THUS FAR HAVE CENTERED AROUND THE USE OF “WATER WINDOW” X-RAYS, HAVING ENERGIES BETWEEN 285 TO 540EV AND FOR WHICH WATER IS TRANSPARENT BUT ORGANIC CONTENT IS ABSORBING. HOWEVER, THERE ARE SEVERAL MAJOR DRAWBACKS TO USING THESE LOW ENERGY X-RAYS: THEY SEVERELY LIMIT THE SIZE OF CELLS THAT CAN BE IMAGED (E.G., <10 ΜM WHEN MANY MAMMALIAN CELLS ARE 10-100 ΜM). THIS SBIR PROPOSAL AIMS TO DEVELOP A 3D NANO X-RAY MICROSCOPE CAPABLE OF HIGH THROUGHPUT (~30 MINUTE) 3D IMAGING OF CRYOGENICALLY PRESERVED CELLS OF UP TO 80 ΜM IN DIAMETER AT DOWN TO 30NM RESOLUTION. THE SYSTEM UTILIZES THE PHENOMENON OF ZERNIKE PHASE CONTRAST AT HIGHER (2.7 KEV) ENERGY X-RAYS, WHICH CAN ACHIEVE EVEN HIGHER CONTRAST FOR BIOLOGICAL SAMPLES THAN WATER WINDOW X-RAYS. ADDITIONALLY, THE SYSTEM WILL ENABLE SEVERAL MAJOR ADVANTAGES OVER WATER WINDOW X-RAY MICROSCOPY, INCLUDING MUCH LARGER CELL IMAGING (80ΜM VS. 10ΜM), LARGER DEPTH-OF- FIELD FOR HIGHER 3D RESOLUTION, AND PRACTICAL BENEFITS (MORE STABLE X-RAY SOURCE AND LARGER WORKING DISTANCE TO INCORPORATE CORRELATIVE TECHNIQUES). THE MICROSCOPE USES THE COMPANY’S PATENTED HIGH BRIGHTNESS X-RAY SOURCE AND PROPRIETARY X-RAY OPTIC TECHNOLOGY. THE PROJECT WILL DEVELOP THE PROPOSING COMPANY’S EXISTING 2.7 KEV AMBIENT SYSTEM TO ENABLE CRYOGENIC OPERATION AND OPTIMIZE ITS PERFORMANCE FOR CELLULAR IMAGING. THE PROPOSED PHASE II 24-MONTH PROJECT IS TO DEVELOP A COMPLETE CRYOGENIC 2.7 KEV SYSTEM FOR CELLULAR IMAGING AND TO EXPERIMENTALLY DEMONSTRATE ITS PERFORMANCE ON MAMMALIAN CELLS.

Project Grant (B) · National Institutes of Health · to Sigray, Inc. (UEI H5UJCPYHJM34) · data as of 2026-11-05

Obligated to date$732.5K3 actions
Period2023-09-20 → 2026-04-24first to last action

What it is

Program
Biomedical Research and Research Training (Assistance Listing 93.859)
Where the work is
Contra Costa, CA · district CA-10

The research project

Cryogenic High-throughput Cellular Imaging System · National Institute of General Medical Sciences (NIGMS) · led by Wenbing Yun, SIGRAY, INC.

“X-ray microscopy has evolved into an important ultrastructure imaging approach for visualizing and measuring intact cells in three dimensions.” Full abstract on RePORTER ↗

NIH research categories: Bioengineering · Biomedical Imaging

NIH funding by fiscal year: FY2022 $998.0K · FY2023 $732.5K ($1.73M in all) · project period 2022-09-10 to 2025-08-31.

Source: NIH RePORTER, project R44GM148148. RePORTER counts NIH's awards by year; USAspending's obligations above count each action.

Obligations by fiscal year

FY2023$732.5K
FY2025$0
FY2026$0

SpendQuery holds FY2023 on; earlier years are on USAspending.gov.

Subrecipients: where the money went next

No subawards reported for this award. Primes report subawards of $30,000 or more; many awards have none.

Every action

3 actions since 2023-09-20. Each is a modification or amendment with the money it added or took back.

DateAmendmentKindAmountWhat the agency wrote
2026-04-24000Revision$0CRYOGENIC HIGH-THROUGHPUT CELLULAR IMAGING SYSTEM - PROJECT SUMMARY/ABSTRACT X-RAY MICROSCOPY HAS EVOLVED INTO AN IMPORTANT ULTRASTRUCTURE IMAGING APPROACH FOR VISUALIZING AND MEASURING INTACT CELLS IN THREE DIMENSIONS. BEAMLINES DEDICATED TO CELLULAR…
2025-01-23000Revision$0CRYOGENIC HIGH-THROUGHPUT CELLULAR IMAGING SYSTEM - PROJECT SUMMARY/ABSTRACT X-RAY MICROSCOPY HAS EVOLVED INTO AN IMPORTANT ULTRASTRUCTURE IMAGING APPROACH FOR VISUALIZING AND MEASURING INTACT CELLS IN THREE DIMENSIONS. BEAMLINES DEDICATED TO CELLULAR…
2023-09-20000Continuation$732.5KCRYOGENIC HIGH-THROUGHPUT CELLULAR IMAGING SYSTEM - PROJECT SUMMARY/ABSTRACT X-RAY MICROSCOPY HAS EVOLVED INTO AN IMPORTANT ULTRASTRUCTURE IMAGING APPROACH FOR VISUALIZING AND MEASURING INTACT CELLS IN THREE DIMENSIONS. BEAMLINES DEDICATED TO CELLULAR…

Source: USAspending.gov prime award transactions and FSRS subaward reports, as loaded by SpendQuery (data as of 2026-11-05). Amounts are obligations (money committed), not outlays. The official record on USAspending.gov ↗