R44MH140338↗

Nalu Scientific, LLC received this grant or assistance award from National Institutes of Health: $1.96M obligated so far for mental health research grants. Its latest action was on 2026-06-25.

Key facts · data as of Nov 21, 2026

Recipient
Nalu Scientific, LLC
Awarding agency
National Institutes of Health (Department of Health and Human Services)
Obligated to date
$1.96M

Source: USAspending.gov prime award records (obligations: money committed, not outlays), data as of Nov 21, 2026.

Cite this page: SpendQuery, Award R44MH140338, data as of Nov 21, 2026, https://spendquery.com/award?id=ASST_NON_R44MH140338_075

DESIGN AND DEVELOPMENT OF SYMPET: SYSTEM ON CHIP MODULAR READOUT FOR HIGH-RESOLUTION TOF-PET - PROJECT SUMMARY NALU SCIENTIFIC LLC (NSL) PROPOSES TO DEVELOP AND OPTIMIZE THE DESIGN OF A SILICON PHOTOMULTIPLIER (SIPM) BASED, LOW-POWER, HIGH CHANNEL DENSITY, WAVEFORM-DIGITIZING READOUT MICROCHIP FOR TOF-PET THAT WILL INCREASE IMAGE QUALITY AND PROVIDE MORE ACCURATE AND PRECISE QUANTIZATION, WITH THE POTENTIAL TO SIGNIFICANTLY IMPROVE EARLY DIAGNOSIS OR LOWER EXPOSURE WHILE ALSO ALLOWING GREATER FLEXIBILITY IN THE DEVELOPMENT OF PERSONALIZED PATIENT IMAGING STRATEGIES. THE KEY IDEA BEHIND THE PROJECT IS THAT OF USING THE INFORMATION OF THE FULL WAVEFORM ACQUIRED FROM THE SENSORS THAT CAN PROVIDE INFORMATION TO OVERCOME THE LIMITATIONS OF TRADITIONAL APPROACHES, LIKE THE VERY FINE ACCURACY IN THE THRESHOLD DEFINITION, DEPENDENCE ON LOW AND HIGH FREQUENCY NOISE, NECESSITY OF AD-HOC CORRECTIONS FOR WAVEFORM AMPLITUDE (“TIME-WALK”) AND SHAPE VARIATION, AND IMPRECISE ENERGY INFORMATION, AS WELL AS NO INFORMATION ABOUT DEPTH OF INTERACTION. NSL’S PATENTED WAVEFORM-DIGITIZING “SYSTEM ON CHIP” READOUT ASIC TECHNOLOGY HAS THE POTENTIAL TO SUBSTANTIALLY IMPROVE TOF-PET IMAGING FROM ITS CURRENT STATE. DURING PHASE I, WE DEVELOPED ANALYTIC MODELING OF LIGHT PRODUCTION AND TRANSPORT IN SCINTILLATING CRYSTALS, ALONG WITH REALISTIC SIMULATIONS OF SENSOR AND READOUT ELECTRONICS IN ORDER TO DERIVE BASELINE TECHNICAL SPECIFICATIONS FOR A WFD READOUT CHIP. WE THEN IMPLEMENTED A MACHINE LEARNING MODEL TO HARVEST AND DEMONSTRATE THE BENEFITS OF WFD. IN PHASE II, WE WILL COMPLETE THE DESIGN, FABRICATE AND TEST A SIPM-BASED, LOW-POWER, HIGH CHANNEL DENSITY, WAVEFORM-DIGITIZING READOUT MICROCHIP FOR TOF-PET, AND VALIDATE THE CONCEPT BY DEVELOPING AND TESTING A PET SUBSYSTEM AS A DEMONSTRATOR. WE WILL COLLABORATE WITH DR. HAMID SABET (HARVARD) IN IMPROVING THE MODELING OF PHASE I, DEFINING THE ADVANTAGES AND LIMITATIONS OF THE USE OF WAVEFORM INFORMATION IN A FULL PET SYSTEM SETTING, AND IMPLEMENTING A FLAT-PANEL PET DETECTOR DEMONSTRATOR. THE PROJECT SPECIFIC AIMS ARE 1: DESIGN AND FABRICATE WAVEFORM DIGITIZER CHIP FOR PET APPLICATIONS. 2: DESIGN AND FABRICATE A DAQ SYSTEM FOR PET INCORPORATING THE WFD READOUT CHIP. 3: WFD-BASED DETECTOR ASSEMBLY INTEGRATION AND CHARACTERIZATION. IN PHASE II, IN ORDER TO REACH THE SPECIFIC AIMS, WE WILL COMPLETE THE DESIGN OF THE PROTOTYPE CHIP FOLLOWING THE SPECIFICATIONS DERIVED IN PHASE I, USING STATE OF THE ART TOOLS TO CONFIRM THE FUNCTIONALITY AND PERFORMANCE OF THE CHIP BEFORE FABRICATION AND VERIFYING IT WITH THOROUGH TESTING. WE THEN WILL FABRICATE A DAQ SYSTEM CAPABLE OF SYNCHRONIZING MULTIPLE COPIES OF THE READOUT CHIP AND HANDLING EXPECTED DATA RATES FROM REALISTIC TOF-PET DETECTOR ENVIRONMENTS, AND FINALLY EVALUATE THEM IN A REALISTIC CONDITION USING PHANTOM TESTING. THE SUCCESSFUL COMPLETION OF THE WORK IS EXPECTED TO RESULT IN THE DEFINITION OF A NOVEL READOUT DEVICE AND SYSTEM THAT COULD PROVE TRANSFORMATIVE FOR THE FIELD OF NEXT GENERATION PET SCANNERS.

Project Grant (B) · National Institutes of Health · to Nalu Scientific, LLC (UEI ZFYUKU9F8TQ4) · data as of 2026-11-21

Obligated to date$1.96M5 actions
Period2024-09-04 → 2026-06-25first to last action
Passed on$179.9Kto 1 subrecipient

What it is

Program
Mental Health Research Grants (Assistance Listing 93.242)
Where the work is
Honolulu, HI · district HI-01

The research project

Design and Development of SyMPET: System on chip Modular readout for high-resolution TOF-PET · National Institute of Mental Health (NIMH) · led by Luca Macchiarulo, NALU SCIENTIFIC, LLC

“Nalu Scientific LLC (NSL) proposes to develop and optimize the design of a silicon photomultiplier (SiPM) based, low-power, high channel density, waveform-digitizing readout microchip for TOF-PET that will increase image quality and provide more accurate and precise quantization, with the potential to significantly…” Full abstract on RePORTER ↗

NIH research categories: Bioengineering · Biomedical Imaging · Mental Health · Networking and Information Technology R&D (NITRD)

NIH funding by fiscal year: FY2024 $1.02M · FY2025 $938.4K ($1.96M in all) · project period 2021-09-30 to 2027-08-31.

Source: NIH RePORTER, project R44MH140338. RePORTER counts NIH's awards by year; USAspending's obligations above count each action.

Obligations by fiscal year

FY2024$1.02M
FY2025$938.4K
FY2026$0

SpendQuery holds FY2023 on; earlier years are on USAspending.gov.

Subrecipients: where the money went next

1 subaward totaling $179.9K (9.2% of what was obligated), as Nalu Scientific, LLC reported them. Primes report subawards of $30,000 or more; smaller ones and unreported ones aren't here.

SubrecipientAmountSubawardsWhereFirstLast
The General Hospital Corporation$179.9K1MA2025-03-262025-03-26
The largest single subawards
DateToAmountFor
2025-03-26The General Hospital Corporation$179.9KMGH WILL DEVELOP NEW DETECTORS FOR THE PROPOSED SYMPET CHIP FOR USE IN TOF-PET APPLICATIONS.

Every action

5 actions since 2024-09-04. Each is a modification or amendment with the money it added or took back.

DateAmendmentKindAmountWhat the agency wrote
2026-06-25000Revision$0DESIGN AND DEVELOPMENT OF SYMPET: SYSTEM ON CHIP MODULAR READOUT FOR HIGH-RESOLUTION TOF-PET - PROJECT SUMMARY NALU SCIENTIFIC LLC (NSL) PROPOSES TO DEVELOP AND OPTIMIZE THE DESIGN OF A SILICON PHOTOMULTIPLIER (SIPM) BASED, LOW-POWER, HIGH CHANNEL DENSITY,…
2025-08-28002Continuation$938.4KDESIGN AND DEVELOPMENT OF SYMPET: SYSTEM ON CHIP MODULAR READOUT FOR HIGH-RESOLUTION TOF-PET - PROJECT SUMMARY NALU SCIENTIFIC LLC (NSL) PROPOSES TO DEVELOP AND OPTIMIZE THE DESIGN OF A SILICON PHOTOMULTIPLIER (SIPM) BASED, LOW-POWER, HIGH CHANNEL DENSITY,…
2025-02-13001Revision$0DESIGN AND DEVELOPMENT OF SYMPET: SYSTEM ON CHIP MODULAR READOUT FOR HIGH-RESOLUTION TOF-PET - PROJECT SUMMARY NALU SCIENTIFIC LLC (NSL) PROPOSES TO DEVELOP AND OPTIMIZE THE DESIGN OF A SILICON PHOTOMULTIPLIER (SIPM) BASED, LOW-POWER, HIGH CHANNEL DENSITY,…
2024-11-15000Revision$0DESIGN AND DEVELOPMENT OF SYMPET: SYSTEM ON CHIP MODULAR READOUT FOR HIGH-RESOLUTION TOF-PET - PROJECT SUMMARY NALU SCIENTIFIC LLC (NSL) PROPOSES TO DEVELOP AND OPTIMIZE THE DESIGN OF A SILICON PHOTOMULTIPLIER (SIPM) BASED, LOW-POWER, HIGH CHANNEL DENSITY,…
2024-09-04000Continuation$1.02MDESIGN AND DEVELOPMENT OF SYMPET: SYSTEM ON CHIP MODULAR READOUT FOR HIGH-RESOLUTION TOF-PET - PROJECT SUMMARY NALU SCIENTIFIC LLC (NSL) PROPOSES TO DEVELOP AND OPTIMIZE THE DESIGN OF A SILICON PHOTOMULTIPLIER (SIPM) BASED, LOW-POWER, HIGH CHANNEL DENSITY,…

Source: USAspending.gov prime award transactions and FSRS subaward reports, as loaded by SpendQuery (data as of 2026-11-21). Amounts are obligations (money committed), not outlays. The official record on USAspending.gov ↗