| R44HD107718↗ | Department of Health and Human Services | BARRON ASSOCIATES, INC. | PROJECT GRANT (B) | 2026-05-14 | 2026-05-14 | 1 | VIRTUAL ACTIVITIES OF LIVING FOR OCCUPATIONAL REHABILITATION - PROJECT SUMMARY/ABSTRACT INTRODUCTION: THE VIRTUAL ACTIVITIES OF LIVING FOR OCCUPATIONAL REHABILITATION (VALOR) SBIR PROGRAM SUPPORTS TELEHEALTH DELIVERY AND REMOTE MONITORING OF UPPER EXTREMITY (UE) STROKE REHABILITATION THROUGH IMMERSIVE PRACTICE OF VIRTUAL ACTIVITIES OF DAILY LIVING (ADLS) AND INSTRUMENTAL ADLS (IADLS). THE VALOR SYSTEM MARRIES GROUND-BREAKING UNTETHERED VIRTUAL REALITY (VR) HEADSET TECHNOLOGY AND DEEP LEARNING RUNTIME 3D HUMAN MOTION TRACKING WITH A LIBRARY OF DIGITAL ADL/IADL THERAPY GAMES TO ENABLE FUNCTIONAL, REPETITIVE TASK PRACTICE AT HOME WITH TELEHEALTH SUPPORT. KEY DIFFERENTIATORS FROM OTHER VR THERAPY OFFERINGS ARE (1) PRACTICE OF ADLS/IADLS (NOT JUST GAMES) INVOLVING REALISTIC ACTIVITIES AND MANUAL INTERACTION, (2) FULLY IMMERSIVE, ECOLOGICALLY VALID ENVIRONMENTS, (3) DRAMATIC SIMPLIFICATION OF SYSTEM HARDWARE BY USING THE TRACKING CAMERAS BUILT INTO THE VR HEADSET TO TRACK THE UES (NO ADDITIONAL SENSORS REQUIRED), AND (4) AN ORDER OF MAGNITUDE COST REDUCTION ENABLING AT HOME USE. PROBLEM TO BE ADDRESSED: VALOR ADDRESSES THE CRITICAL CHALLENGES OF: (1) IMPROVING OUTCOMES IN UE STROKE THERAPY THROUGH REPETITIVE TASK PRACTICE AND MENTAL IMAGERY THAT PROMOTE FUNCTIONAL RECOVERY; (2) ENABLING INCREASED DOSAGE, INTENSITY, AND DURATION THROUGH INDEPENDENT HOME USE AND TELETHERAPY; (3) MINIMIZING TOTAL COST OF REHABILITATION BY REDUCING PATIENT/THERAPIST TRAVEL; AND (4) IMPROVING STROKE THERAPY SERVICES TO UNDERSERVED POPULATIONS AND REGIONS. LONG-TERM GOAL: IMPROVED OUTCOMES AND FUNCTIONAL INDEPENDENCE FOR PATIENTS WITH ACQUIRED BRAIN INJURY. PHASE I RESULTS: A SUCCESSFUL VALOR SBIR PHASE I PILOT STUDY CONDUCTED BY DUKE UNIVERSITY COMPLETED BY 16 STROKE PATIENTS (44% BLACK OR AFRICAN AMERICAN) HAS ESTABLISHED THE USABILITY AND TECHNOLOGY ACCEPTANCE OF A PROTOTYPE IMMERSIVE VR SYSTEM FOR UE THERAPY. CAREFUL DESIGN OF THE VR ACTIVITIES RESULTED IN EXCELLENT (LOW) CYBERSICKNESS SCORES. THE EFFORT ALSO DEMONSTRATED THE VALIDITY OF METRICS DERIVED DURING IMMERSIVE VIRTUAL ADL/IADL PRACTICE FOR TRACKING A PATIENT’S UE MOTOR STATUS, ENABLING TELEHEALTH MONITORING AND DELIVERY. PHASE II SUMMARY: A VALOR PHASE II WILL INCLUDE: (1) DEVELOPMENT OF A MARKET-READY PRODUCT WITH A TEN-FOLD REDUCTION IN COST COMPARED TO EXISTING VR THERAPY SYSTEMS; (2) A PHASE II RATER-BLINDED RCT THAT PROVIDES EFFICACY AND SAFETY DATA REQUIRED FOR REGULATORY COMPLIANCE; (3) ESTABLISHING CONFORMITY WITH APPLICABLE FDA, FCC, ISO, AND IEC REGULATIONS AND STANDARDS; AND (4) PREPARATION OF FDA CLEARANCE AND CE MARKING PACKAGES. COMMERCIAL OPPORTUNITY: APPROXIMATELY 50% OF THE 800,000 INDIVIDUALS HOSPITALIZED DUE TO STROKE EACH YEAR IN THE U.S. SUFFER FROM CHRONIC DEFICITS IN HAND AND/OR ARM FUNCTION [1], [2]. VALOR IS POISED TO RAPIDLY TRANSITION THE PHASE II PRODUCT TO MARKET BY LEVERAGING AN EXISTING BRAND WITH WELL-DEFINED DISTRIBUTION CHANNELS. | $1.11M |
| N6833524C0188↗ | Department of Defense | BARRON ASSOCIATES, INC. | DEFINITIVE CONTRACT | 2025-10-01 | 2026-03-16 | 2 | RESEARCH AND DEVELOPMENT | $379.8K |
| FA945319C0005↗ | Department of Defense | BARRON ASSOCIATES, INC. | DEFINITIVE CONTRACT | 2025-12-02 | 2026-04-22 | 4 | AUTONOMOUS OPERATIONS FOR RESILIENT & TACTICAL ACTION (AORTA) | $373.8K |
| R43HL184377↗ | Department of Health and Human Services | BARRON ASSOCIATES, INC. | PROJECT GRANT (B) | 2026-08-04 | 2026-08-04 | 1 | ACUTE DECOMPENSATION AVOIDANCE IN HEART FAILURE PATIENTS - SUMMARY/ABSTRACT HEART FAILURE (HF) IS A LEADING CAUSE OF MORBIDITY, MORTALITY, AND HOSPITALIZATION. HF IS THE SECOND-MOST-COMMON MEDICARE INPATIENT DIAGNOSIS, WITH ONE OF THE HIGHEST 30-DAY READMISSION RATES OF ANY ILLNESS. MONITORING OF HF PATIENTS REMAINS CHALLENGING. IN THE HOSPITAL, RIGHT HEART CATHETERIZATION (RHC) IS COMMONLY USED FOR COMPRE- HENSIVE EVALUATION AND MANAGEMENT OF HF PATIENTS. IN THE HOME, HF MONITORING GENERALLY RELIES ON THE DETECTION OF SYMPTOMS, SUCH AS DYSPNEA, AND NONSPECIFIC PHYSICAL EXAM FINDINGS RELATED TO EDEMA, SUCH AS WEIGHT GAIN. SUCH MEASURES ARE SUBJECTIVE AND NOT SUFFICIENTLY SENSITIVE TO BE TRANSLATED INTO EARLY DETECTION AND INTERVENTION. ACUTE DECOMPENSATED HF (ADHF) IS DEFINED AS THE SUDDEN OR GRADUAL ONSET OF THE SIGNS OR SYMPTOMS OF HF AND IS CHARACTERIZED BY VARYING DEGREES OF HEMODYNAMIC CHANGE — E.G., INCREASED HEART FILLING PRESSURES AND DE- CREASED CARDIAC OUTPUT (CO). HEMODYNAMIC ASSESSMENT IS CRITICAL TO THE ACCURATE EVALUATION OF HF, PARTICULARLY IN ADHF, BUT CURRENTLY REQUIRES INVASIVE RHC; AS A SERIOUS INTERVENTION, RHC IS RARELY PERFORMED IN HOSPITALIZED ADHF PATIENTS. THE ABILITY TO NONINVASIVELY TRACK HEMODYNAMIC CHANGES IN HOME AND HOSPITALIZED HF PATIENTS OFFERS STRONG POTENTIAL TO IMPROVE CARE IN BOTH GROUPS AND TO REDUCE HOSPITALIZATIONS AND REHOSPITALIZATIONS. RECENTLY APPROVED REMOTE IMPLANTABLE HEMODYNAMIC MONITORING (VIZ., CARDIOMEMS) HAS SHOWN PROMISE TO REDUCE HF PATIENT HOSPITAL ADMISSIONS, BUT IS COSTLY AND REQUIRES AN INVASIVE PROCEDURE, WHICH MAKES IT IMPRACTICAL FOR MOST PATIENTS. THERE IS AN UNMET NEED FOR A LOW-COST, NONINVASIVE HEMODYNAMIC MONITORING TOOL. CIRCULATION TIME (CT) REFERS TO THE TIME DELAY BETWEEN THE INJECTION OF AN INDICATOR INTO THE HEART OR LUNGS AND ITS DETECTION DISTALLY. IN ADHF, A PROLONGED CT CAN REFLECT ELEVATED HEART FILLING PRESSURE (PRESSURE OVERLOAD), LOW CO, AND INCREASED PULMONARY TRANSIT TIME (PTT) DUE TO PULMONARY CONGESTION. THE “LUNG-TO-FINGER CT” (LFCT) IS PROLONGED IN THE SETTING OF HF AND IS INVERSELY RELATED TO CO AND PTT. DYNAMIC O2 DESATURATION, SUCH AS OCCURS DURING APNEIC EPISODES IN SLEEP OR BRIEF EXPOSURE TO BREATH HOLDING WHILE AWAKE, CAN BE USED TO MEASURE THE LFCT. WE HAVE EXPANDED THE CONCEPT BY HAVING PATIENTS INHALE TWO OR THREE BREATHS OF 100% O2 TO MEASURE LFCT AND DEVELOPED AN EASY MEASUREMENT METHOD CALLED THE ACUTE DECOMPENSATION AVOIDANCE IN PATIENTS (ADAPT) SYSTEM. PILOT DEMONSTRATION SHOWS THAT THE 100% O2 LFCT METHOD IS FEASIBLE AND REPRODUCIBLE WITHIN SUBJECTS. WITH ITS NONINVASIVENESS, SIMPLICITY, LOW COST, AND PLEASANTNESS, IT HOLDS PROMISE FOR USE BY HF PATIENTS IN BOTH HOME AND HOSPITAL SETTINGS. ADAPT WILL MONITOR AND AUTOMATICALLY REPORT SIGNIFICANT INCREASES IN LFCT, INDICATING HEMODYNAMIC WORSENING OR INCIPIENT DECOMPENSATION. PHASE I WILL ASSESS AND DEMONSTRATE THE FEASIBILITY OF THE ADAPT SYSTEM IN ADMITTED ADHF PATIENTS BEFORE AND AFTER HOSPITAL TREATMENT FOR DECOMPENSATION, WHERE LFCT VALUES SHOULD DECREASE SIGNIFICANTLY FOLLOWING HOSPITAL INTERVENTIONS. ADDITIONALLY, HEMODYNAMIC MEASURES FROM NON-HF PATIENTS UNDERGOING RHC WILL BE COR- RELATED WITH THEIR LFCTS. THIS WILL INCLUDE PATIENTS WITH DIFFERENT COMBINATIONS OF FILLING PRESSURES AND COS. | $351.4K |
| FA239126CB001↗ | Department of Defense | BARRON ASSOCIATES, INC. | DEFINITIVE CONTRACT | 2026-04-17 | 2026-05-26 | 2 | RUNTIME ASSURANCE SYSTEM DEVELOPMENT | $194.3K |
| R43AG082574↗ | Department of Health and Human Services | BARRON ASSOCIATES, INC. | PROJECT GRANT (B) | 2025-12-02 | 2025-12-02 | 1 | A NOVEL INSTRUMENT FOR CONTINUOUS BLOOD PRESSURE MONITORING - PROJECT SUMMARY/ABSTRACT PROBLEM HIGH BLOOD PRESSURE (BP) IS A SUBSTANTIAL PUBLIC HEALTH PROBLEM THAT AFFECTS 45% OF ADULTS (75% OF INDIVIDUALS OVER AGE 65) AND IS A LEADING CAUSE OF EXCESS CARDIOVASCULAR MORBIDITY AND MORTALITY. BP MONITORING HAS HIGH DIAGNOSTIC AND PROGNOSTIC VALUE AS AN IMPORTANT MARKER OF CARDIOVASCULAR DISEASE. STATIC BP SNAPSHOTS, WHICH ARE TYPICALLY OBTAINED VIA SPHYGMOMANOMETRY DURING DOCTOR’S OFFICE VISITS, HAVE DOCUMENTED RELIABILITY ISSUES, INCLUDING “WHITE-COAT” HYPERTENSION AND POOR TECHNIQUE. AUSCULTATORY OR OSCILLOMETRIC CUFF-BASED AMBU- LATORY BP MONITORS (ABPMS) THAT CAN BE WORN IN HOME SETTINGS AND PROVIDE REGULAR AUTOMATED MEASUREMENTS OVER 24-HOUR PERIODS HAVE SEEN WIDESPREAD ADOPTION. HOWEVER, THESE DEVICES ALSO SUFFER FROM POOR RELIABILITY BECAUSE MEASUREMENTS ARE SELDOM PERFORMED ACCORDING TO THE SPECIFIED GUIDELINES EVEN WITH TRAINING (E.G., SEATED, FEET NOT CROSSED, ARM CUFF MAINTAINED AT HEART LEVEL, ETC.). THEY ALSO YIELD ONLY INTERMITTENT MEASURE- MENTS (POTENTIALLY MISSING IMPORTANT BP EVENTS), WORSEN SLEEP QUALITY DUE TO THEIR INTRUSIVENESS, CONFOUND BP MEASUREMENTS DUE TO AUTONOMIC RESPONSE TO CUFF INFLATIONS, AND ARE OBTRUSIVE AND UNCOMFORTABLE. SOLUTION THE PROPOSED BLOOD PRESSURE SAGE (BP-SAGE ) SYSTEM WILL BE A NOVEL, RELIABLE, EASY-TO-USE, AND COMFORTABLE (NON-CUFF-BASED) CONTINUOUS ABPM (CABPM) THAT CAN OPERATE 24/7, EVEN DURING ACTIVITIES OF DAILY LIVING (ADL) AND SLEEP WITHOUT DISTURBING OR REQUIRING ANY ACTION FROM THE WEARER, AND WITHOUT IMPOSING STRINGENT MEASUREMENT GUIDELINES. THIS NEW CLASS OF BP MONITOR WILL BE AN IMPORTANT ADDITION TO CLINICAL PRACTICE, ACCURATELY AND UNOBTRUSIVELY ASSESSING INDIVIDUALS WITH ESTABLISHED OR SUSPECTED HYPERTENSION, EVEN DURING MOVEMENT AND WITHOUT UNCOM- FORTABLE CUFF INFLATIONS. BP-SAGE WILL PROVIDE ACCURATE BP ESTIMATES WITHOUT RESTRICTING USERS’ MOBILITY, BODY POSTURES, OR ARM ELEVATIONS. THE BEAT-TO-BEAT BP ESTIMATES MAY BE USED DIRECTLY OR AVERAGED OVER ARBITRARY INTERVALS (E.G., TO REPRODUCE CONVENTIONAL ABPM RESULTS). THE PHASE I EFFORT WILL DEMONSTRATE PROOF-OF-CONCEPT AND FEASIBILITY FOR THE BP-SAGE METHODOLOGY VIA RIGOROUS EVALUATION IN BOTH HEALTHY AND HYPERTENSIVE SUBJECTS. IN PARTICULAR, BP-SAGE SYSTOLIC, DIASTOLIC, AND MEAN ARTERIAL BP ESTIMATES WILL BE OBTAINED DURING REST AND AT DIFFERENT BP LEVELS AND COMPARED TO CRITERION BP MEASUREMENTS OBTAINED USING A LABORATORY-GRADE CONTINUOUS NONINVASIVE BP (CNIBP) MONITOR. AS A TRUE PULSE TRANSIT TIME (PTT)-BASED TECHNIQUE, AND BASED ON THE PROPOSED NOVEL MODELING APPROACH THAT ALSO ACCOUNTS FOR VARIATIONS IN VASOMOTOR TONE, BP-SAGE WILL OBVIATE THE NEED FOR REPEATED CALIBRATIONS ASSOCIATED WITH TRADITIONAL PULSE ARRIVAL TIME (PAT)-BASED METHODS. BP-SAGE SOFTWARE WILL AUTOMATICALLY GENERATE CLEAR, INTERPRETIVE REPORTS THAT MEET INTERNATIONAL STANDARDS AND INCLUDE SUMMARY DATA TO SIMPLIFY INTERPRETATION BY CLINICIANS. BP-SAGE WILL FULFILL THE NEED FOR AN ERGONOMIC, ACCURATE, RELIABLE, AND LOW-COST CONTINUOUS BP MONITORING FOR USE IN HEALTHCARE AND CLINICAL RESEARCH. | $0 |
| R44AG056224↗ | Department of Health and Human Services | BARRON ASSOCIATES, INC. | PROJECT GRANT (B) | 2025-12-02 | 2025-12-02 | 1 | A SYSTEM TO DETECT FALL OCCURRENCE AND LOCATION IN HOSPITAL SETTINGS - PROJECT SUMMARY/ABSTRACT PROBLEM FALL DETECTION, ASSESSMENT, AND PREVENTION IS A CHALLENGING ISSUE FOR HEALTHCARE INSTITUTIONS. DESPITE WIDE RECOGNITION AS A CONSIDERABLE PROBLEM, FALL-RELATED INJURIES ARE THE MOST FREQUENTLY REPORTED ADVERSE EVENTS IN HOSPITAL INPATIENT SETTINGS|UP TO 20% OF PATIENTS FALL AT LEAST ONCE DURING THEIR STAY. ACCORDING TO THE AGENCY FOR HEALTHCARE RESEARCH AND QUALITY REPORTS, 30% TO 51% OF FALLS RESULT IN INJURY, AND UP TO 44% OF THOSE INJURIES LEAD TO DEATH. IN THE UNITED STATES ALONE, THE NUMBER OF INPATIENT FALLS EXCEEDS 1 MILLION PER YEAR, WITH ELDERLY INDIVIDUALS BEING THE MOST VULNERABLE. AS A TESTAMENT TO ITS IMPORTANCE, FALL RESEARCH WAS LISTED AS A TOP PRIORITY IN THE INSTITUTE OF MEDICINE'S REPORT TO CONGRESS ON NATIONAL PRIORITIES. DIVERSE FACTORS CONTRIBUTE TO FALLS: PATIENT FACTORS (E.G., COGNITIVE STATE, MUSCLE WEAKNESS, MEDICATIONS), ENVIRONMENTAL FACTORS (E.G., BED/TOILET POSITIONING, TRIP HAZARDS), AND INSTITUTIONAL FACTORS (E.G., POOR RESPON- SIVENESS TO BED/CHAIR ALARMS, INADEQUATE FALL ASSESSMENT AND PREVENTION MEASURES). ALTHOUGH HOSPITALS EMPLOY PROGRAMS TO PREVENT FALLS, AN ESSENTIAL COMPONENT OF A FALL PREVENTION PROGRAM IS ACCURATE DETERMINATION OF FALL EVENTS, AS MANY FALLS ARE UNSEEN AND UNREPORTED. IN THEIR 2016 CLAIMS REPORT, INSURANCE COMPANY CNA STATED THAT 66% OF FALLS WERE UNWITNESSED AND CITED FAILURE TO MONITOR FOR FALLS IN OVER HALF OF CLOSED LEGAL CLAIMS. ALTERNATIVE FALL DETECTION SOLUTIONS HAVE NOT BEEN ADOPTED IN HOSPITAL SETTINGS DUE TO POOR FALL SENSITIVITY, HIGH FALSE-ALARM RATES, AND LACK OF NECESSARY SUPPORTING FUNCTIONS. SOLUTION THE BODY-WORN FALLCALL SYSTEM, PROPOSED HEREIN, WILL LEVERAGE POWERFUL, NOVEL SENSING CAPABILITIES TO PROVIDE ROBUST FALL DETECTION AND TO REPORT FALL LOCATION WITHOUT BOTHERSOME FALSE ALARMS. THE FALLCALL BODY-WORN INSTRUMENT WILL EMBODY A MINIATURE ELECTRONICS PACKAGE THAT IS ENCAPSULATED IN A DISPOSABLE, HYPOALLERGENIC ADHESIVE PATCH. THE PATCH CAN BE PLACED ANYWHERE ON THE TORSO OR UPPER ARMS TO MINIMIZE INTERACTION WITH OTHER MEDICAL EQUIPMENT OR INJURY SITES. THE SYSTEM WILL CONTINUOUSLY MONITOR PATIENTS AND ISSUE A TIMELY ALERT IF A FALL IS DETECTED, MINIMIZING PATIENT TIME ON THE GROUND, AS WELL AS INJURY ASSESSMENT AND TREATMENT LATENCIES. THE FALLCALL SYSTEM WILL ALLOW PATIENT LOCATION TO BE DETERMINED (INCLUDING THE ROOM AND OOR OF THE HOSPITAL) USING A RELIABLE, ROBUST WIRELESS MESH NETWORK. ADDITIONALLY, THE FALLCALL SYSTEM WILL HAVE THE CAPABILITY TO ISSUE WANDER AND INACTIVITY ALERTS. THE PROPOSED SYSTEM WILL BE UNIQUE IN ITS ABILITY TO OBJECTIVELY MEASURE THE RESPONSE TIME OF CLINICAL STA WHEN A FALL OCCURS, AND WILL BE A KEY COMPONENT IN EVALUATING AND IMPROVING FALL PREVENTION PROGRAMS. PHASE I RESULTS THE PHASE I E ORT BUILT AND EVALUATED THE FALLCALL PROTOTYPE IN BOTH A FALL LABORATORY AND REAL-WORLD HOSPITAL SETTING USING PATIENTS. THE STUDIES RESULTED IN 100% OF FALLS DETECTED WITH ZERO FALSE ALARMS. LOCATION DETERMINATION ALSO ACHIEVED PERFECT ACCURACY. A FORMAL USABILITY STUDY WAS CONDUCTED RESULTING IN A GRADE IN THE TOP 5% BASED ON NORMATIVE DATA. | $0 |
| R44AG062069↗ | Department of Health and Human Services | BARRON ASSOCIATES, INC. | PROJECT GRANT (B) | 2026-03-18 | 2026-03-18 | 1 | KNEE-BIOFEEDBACK REHABILITATION INTERFACE FOR GAME-BASED HOME THERAPY (KNEEBRIGHT) - PROJECT SUMMARY/ABSTRACT SIGNIFICANCE: THE KNEE BIOFEEDBACK REHABILITATION INTERFACE FOR GAME-BASED HOME THERAPY (“KNEEBRIGHT”) SYSTEM COMBINES ELECTROMYOGRAPHY (EMG) BIOFEEDBACK WITH VIDEO GAME THERAPY (VGT) TO PROVIDE KNEE OSTEOARTHRITIS (OA) PATIENTS WITH AN ENGAGING, EFFECTIVE TOOL FOR CONDUCTING REHABILITATION EXERCISES AT HOME. KNEEBRIGHT AIMS TO MOTIVATE OA PATIENTS TO CONDUCT REGULAR MUSCLE STRENGTHENING EXERCISE THROUGH AN ENGAGING, EMG-DRIVEN VIRTUAL WORLDS THERAPY. THE SYSTEM COMBINES WIRELESS EMG ELECTRODES THAT ARE CONVENIENT FOR PATIENTS TO USE IN A HOME SETTING WITH SOFTWARE THAT PROVIDES AUTOMATED GUIDANCE THROUGH EVIDENCE-BASED, PROGRESSIVE EXERCISE ROUTINES. IMPORTANTLY, THESE EXERCISES ARE PRESENTED TO THE PATIENT IN THE FORM OF FUN AND ENGAGING ACTIVITIES TO PROMOTE A POSITIVE EXPERIENCE AND ENCOURAGE CONTINUED ADHERENCE. PROBLEM TO BE ADDRESSED: OA IS THE LEADING CAUSE OF DISABILITY IN THE UNITED STATES. REHABILITATION THROUGH QUADRICEPS STRENGTHENING IS A WELL-ESTABLISHED, EFFECTIVE TREATMENT FOR KNEE OA BUT PATIENT ADHERENCE TO EXERCISE ROUTINES IS LOW DUE TO LACK OF GUIDANCE REGARDING OPTIMAL PROTOCOLS AND LACK OF ENGAGEMENT DURING THE REPETITIVE ROUTINES THAT PATIENTS FIND TEDIOUS AND BORING. UNSUPERVISED, HOME-BASED EXERCISE IS PARTICULARLY CHALLENGING. INNOVATIVE, ENGAGING SOLUTIONS ARE NEEDED TO ENABLE AND FACILITATE HOME PARTICIPATION, ESPECIALLY GIVEN THE INCREASED THE USE OF TELEHEALTH DUE TO THE COVID19 PANDEMIC. PHASE II RESULTS: THE PHASE II EFFORT SUCCESSFULLY DEVELOPED A FULL-FEATURED KNEEBRIGHT SYSTEM AND DEPLOYED IT IN A 10-WEEK RANDOMIZED, CONTROLLED TRIAL WITH KNEE OA PATIENTS. PARTICIPANTS USING THE KNEEBRIGHT SYSTEM FOR EXERCISE INCREASED THEIR HOME EXERCISE SESSION PARTICIPATION BY 20% COMPARED TO THE CONTROL GROUP. THE STUDY ALSO DEMONSTRATED VERY POSITIVE USABILITY RATINGS AND POSITIVE TRENDS IN STRENGTH AND BALANCE OUTCOMES. PHASE IIB PROGRAM SUMMARY: THE PROPOSED PHASE IIB EFFORT WILL YIELD A COMMERCIAL KNEEBRIGHT SYSTEM SUPPORTING HOME-BASED PHYSICAL THERAPY FOR KNEE OA. NEW DEVELOPMENTS WILL INCLUDE: GAME ENHANCEMENTS TO EXPAND EXERCISE OPTIONS AND DEVICE COMPATIBILITY; UPGRADED SENSOR FEATURES; A SECURE PROVIDER DASHBOARD WEB APPLICATION FOR MONITORING AND GUIDING THERAPY; AND HIPAA COMPLIANT CLOUD SERVICES INTEGRATION. PURSUIT OF FEDERAL REGULATORY APPROVAL FOR THE NEW DEVICE WILL INCLUDE DOCUMENTATION OF SAFETY, CREATION OF A USER’S GUIDE AND OTHER FDA LABELING, AND COMPLETION OF ACTIONS SUPPORTING PREMARKET NOTIFICATION. TO ESTABLISH ACCEPTANCE BY PHYSICAL THERAPY PRACTITIONERS, A NETWORK OF MULTIPLE KNEE OA PHYSICAL THERAPY PROVIDERS WILL PARTICIPATE IN A RANDOMIZED, CONTROLLED CLINICAL TRIAL. AN INNOVATIVE PROVIDER-AS-INVESTIGATOR STUDY MODEL WILL STREAMLINE TRANSLATION OF RESEARCH TO CLINICAL PRACTICE. THE CLINICAL TRIAL WILL EVALUATE THE ABILITY OF THE KNEEBRIGHT SYSTEM, AS PRESCRIBED BY A VARIETY OF PTS, TO ACHIEVE CLINICALLY RELEVANT OUTCOMES. IMPACT: THE SYSTEM WILL HAVE A SUBSTANTIAL AND SUSTAINED IMPACT ON PUBLIC HEALTH BY INCREASING KNEE OA PATIENT ADHERENCE TO HOME EXERCISE AND THEREBY REDUCING PAIN AND RESTORING PHYSICAL FUNCTION. | $0 |