Company profile · federal money

The California Medical Innovations Institute, Inc

Compare ⇄Opportunities that fit →

The California Medical Innovations Institute, Inc (UEI CSLYY6VAHXX7) received $1.26M in federal obligations in FY2026 so far (Defense contracts arrive about 90 days late) in grants and other assistance, the most from Department of Health and Human Services ($1.26M). Its largest award, R01HL166508, was $741.4K from Department of Health and Human Services.

Key facts · data as of Nov 21, 2026

Federal obligations, FY2026 so far
$1.26M
Largest customer
Department of Health and Human Services ($1.26M)

Source: USAspending.gov prime awards (obligations: money committed, not outlays), data as of Nov 21, 2026.

Cite this page: SpendQuery, The California Medical Innovations Institute, Inc federal contracts and awards, data as of Nov 21, 2026, https://spendquery.com/company?key=CSLYY6VAHXX7

UEI CSLYY6VAHXX7 · CAGE 73DP4 · registered in CA

Why these numbers?
  • Sources: USAspending.gov awards and subawards, SAM.gov registrations, state checkbooks; data as of 2026-11-10.
  • A company's totals add up every registration rolled up under it (subsidiaries and locations); corrected parents and ownership changes are listed under its registrations.
  • Subcontracts are what prime contractors report; they are not added to the company's prime awards.
  • Amounts are obligations (money committed) by federal fiscal year (October to September), not outlays (money paid).

How we check the numbers · All sources

Year:
FY2026 obligations
$1.26M
▼ 56.4% vs FY2025
all awards, every registration rolled up
Largest customer
$1.26MDepartment of Health and Human Services
100% of its FY2026 money

Its whole relationship with the federal government

Brief

In FY2026, The California Medical Innovations Institute, Inc received $1.26M in federal awards, down 56% from FY2025. 100% of it came from the Department of Health and Human Services. The most money goes to work done in California.

Written from the numbers on this page, not by AI.

What it does

Reading its website…

Federal money by year

Federal · obligations

all years

Obligations by fiscal year across all loaded years: from $3.82M (2023) to $1.26M (2026).

Obligations by fiscal year
Fiscal yearObligations
2023$3.82M
2024$3.77M
2025$2.90M
2026$1.26M
Why this number?
  • Amounts are obligations (money committed), not outlays (money paid).
  • No year given: covers FY2023–FY2026.
  • Company roll-ups match names and parent companies; some subsidiaries may be missed.
  • Matched: CSLYY6VAHXX7 → THE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INC
  1. Source USAspending.gov prime awards · about the data

Open as a question →

Who pays it, FY2026

Federal · obligations

FY2026

$1.26Mall federal money · largest: Department of Health and Human Services $1.26M (100%)

Top 1 by obligations in FY2026. Leading: Department of Health and Human Services ($1.26M).

Why this number?
  • Amounts are obligations (money committed), not outlays (money paid).
  • Company roll-ups match names and parent companies; some subsidiaries may be missed.
  • Matched: CSLYY6VAHXX7 → THE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INC
  1. Source USAspending.gov prime awards · about the data

Open as a question →

What kind of money, FY2026

Federal · obligations

FY2026

$1.26Mall federal money · largest: grants $1.26M (100%)

Top 1 by obligations in FY2026. Leading: grants ($1.26M).

Award typeObligations
grants$1.26M
Why this number?
  • Amounts are obligations (money committed), not outlays (money paid).
  • Loan amounts are the government's estimated subsidy cost (what the loan is expected to cost it), not the amount lent; ask for loan face value for the amount lent.
  • Award types follow USAspending: grants include cooperative agreements; direct payments include benefits such as Social Security and Medicare; other = insurance and other assistance.
  • Company roll-ups match names and parent companies; some subsidiaries may be missed.
  • Matched: CSLYY6VAHXX7 → THE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INC
  1. Source USAspending.gov prime awards · about the data

Open as a question →

Where the work is, FY2026

Federal · obligations

FY2026

Top 1 by obligations in FY2026. Leading: California ($1.26M).

StateObligations
California$1.26M
Why this number?
  • Amounts are obligations (money committed), not outlays (money paid).
  • Location is where the work is performed, not where the recipient is based.
  • Medicare payments are published as aggregate records placed where Medicare's claims contractors are (mostly Minnesota, Indiana, Pennsylvania, Kentucky, North Dakota, Connecticut, Florida and South Carolina), not where patients live, so those states show far more HHS money than their population suggests (ask for Medicare payments by patients' home state for where beneficiaries live).
  • '(outside the US)' is work performed abroad; '(not reported)' has no location in the source.
  • Company roll-ups match names and parent companies; some subsidiaries may be missed.
  • Matched: CSLYY6VAHXX7 → THE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INC
  1. Source USAspending.gov prime awards · about the data

Open as a question →

Largest awards, FY2026

Federal · obligations

FY2026

Found 4 award(s) in FY2026. The largest is R01HL166508 (THE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INC, Department of Health and Human Services) with $741.37K.

Award idAgencyRecipientAward typeFirst actionLast actionActionsDescriptionObligations
R01HL166508↗Department of Health and Human ServicesTHE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INCPROJECT GRANT (B)2026-08-072026-08-071MATHEMATICAL MODEL-BASED OPTIMIZATION OF CRT RESPONSE IN ISCHEMIA - PROJECT SUMMARY/ABSTRACT APPLICATION OF MULTISCALE COMPUTER MODELING TO HELP GUIDE AND ELUCIDATE HEART DISEASE TREATMENTS IS EMERGING. COMPUTATIONAL MODELING, HOWEVER, HAS NOT BEEN EXPLOITED FOR OPTIMIZING CARDIAC RESYNCHRONIZATION THERAPY (CRT). WHILE CRT HAS EMERGED AS A POWERFUL TREATMENT FOR HEART FAILURE (HF) TO RESTORE NORMAL ACTIVATION PATTERN IN THE HEART, ABOUT 30% OF PATIENTS STILL DO NOT IMPROVE AFTER THERAPY (NON-RESPONDERS). IMPROVEMENT OF RESPONDER RATE THEREFORE REMAINS A CRUCIAL CLINICAL CHALLENGE AND THE HOLY GRAIL OF CRT. WE BELIEVE THAT COMPUTATIONAL MODELING CAN HELP OPTIMIZE CRT AND IMPROVE THE RESPONDER RATE. EQUALLY IMPORTANT, THE DEVELOPMENT OF A MULTISCALE COMPUTATIONAL FRAMEWORK THAT CONSIDERS THE KEY PHYSICS OF THE HEART CAN HELP UNDERSTAND SEVERAL NOVEL PACING THERAPIES (E.G., CONDUCTION SYSTEM PACING (CSP) INCLUDING HIS BUNDLE PACING AND LEFT BRANCH BUNDLE (LBB) PACING) THAT HAVE BEEN DEVELOPED RECENTLY TO IMPROVE THE RESPONDER RATE. SPECIFICALLY, COMPUTATIONAL MODELING CAN HELP ELUCIDATE THE KEY FACTORS AFFECTING THE LONG AND SHORT-TERM EFFECTIVENESS OF THESE PACING THERAPIES IN PATIENTS WITH DIFFERENT INTRAVENTRICULAR CONDUCTION DELAY AND/OR LV SCAR/ISCHEMIA. HERE, THE OVERALL GOAL HERE IS TO DEVELOP COMPUTATIONAL APPROACHES THAT COMBINE MACHINE LEARNING ALGORITHMS AND PHYSICS-BASED MODELING TO FUNDAMENTALLY UNDERSTAND THE SHORT AND LONG-TERM EFFECTS OF CRT THAT INCLUDES CSP, OPTIMIZE CRT, AND TO ELUCIDATE THE ADVANTAGES AND DISADVANTAGES OF CSP OVER STANDARD CRT. THE FOLLOWING SPECIFIC AIMS ARE CONSTRUCTED TO ACCOMPLISH THIS GOAL. FIRST, WE WILL DEVELOP AN EXPERIMENTALLY-VALIDATED MULTISCALE CARDIAC ELECTRO-MECHANICS-PERFUSION (EMP) COMPUTATIONAL FRAMEWORK TO SIMULATE THE CHRONIC EFFECTS OF CRT AND CSP IN TREATING MECHANICAL DYSSYNCHRONY IN LBBB + ISCHEMIA. SECOND, WE WILL INTEGRATE THE COMPUTATIONAL MODELING FRAMEWORK WITH EFFICIENT MACHINE LEARNING AND OPTIMIZATION ALGORITHMS TO OPTIMIZE CRT WITH LV EPICARDIAL AND ENDOCARDIAL PACING IN ISCHEMIA. THIRD, WE WILL USE THE VALIDATED MULTISCALE COMPUTATIONAL EMP FRAMEWORK TO ELUCIDATE THE EFFECTS AND FACTORS AFFECTING THE RESPONSE OF CSP IN ISCHEMIA. THE PROPOSED APPROACH AND METHODOLOGIES ARE INNOVATIVE. MORE IMPORTANTLY, SUCCESSFUL COMPLETION WILL DIRECTLY TRANSLATE THE FINDINGS TO THE CLINIC FOR OPTIMIZATION OF CRT THERAPY TO REDUCE NON-RESPONDER RATES AS WELL AS PATIENT IDENTIFICATION FOR DIFFERENT PACING THERAPIES. THIS WOULD HAVE SUBSTANTIAL IMPACT ON IMPROVING THE TREATMENT AND REDUCING THE COST OF HF EPIDEMIC.$741.4K
R01DK131488↗Department of Health and Human ServicesTHE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INCPROJECT GRANT (B)2026-06-012026-06-011PATHOPHYSIOLOGY, DIAGNOSIS AND BIOFEEDBACK THERAPY IN FECAL INCONTINENCE USING FECOBIONICS - ABSTRACT FECAL INCONTINENCE (FI) AFFECTS 1 IN 7 AMERICANS WITH A RISING INCIDENCE THAT POSES A MAJOR HEALTHCARE BURDEN. ITS PATHOPHYSIOLOGY IS POORLY UNDERSTOOD AND CONSEQUENTLY THERE IS DEARTH OF EFFECTIVE TREATMENT(S). A CRITICAL BARRIER TO PROGRESS HAS BEEN THE LACK OF COMPREHENSIVE, PHYSIOLOGICALLY-RELEVANT AND PRACTICAL DIAGNOSTIC TEST FOR IDENTIFYING THE UNDERLYING MECHANISM(S). CURRENT TESTS PROVIDE EITHER INCOMPLETE OR CONFLICTING INFORMATION THAT DO NOT CORRELATE WITH SYMPTOMS AND TREATMENT OUTCOMES. OUR GOAL IS TO DETERMINE THE ROLE OF ANORECTAL MUSCLES IN MAINTAINING CONTINENCE AND FACILITATING DEFECATION, AND HOW ANORECTAL MALFUNCTIONS CAN CAUSE FI BY USING A NOVEL TECHNOLOGY CALLED FECOBIONICS (AN ELECTRONIC SIMULATED STOOL) TO EVALUATE ITS DIAGNOSTIC AND THERAPEUTIC UTILITY. FECOBIONICS HAS THE CONSISTENCY AND SHAPE OF NORMAL STOOL THAT CAN RECORD PRESSURES, CROSS- SECTIONAL AREA, ORIENTATION, AND VISCOELASTIC PROPERTIES OF THE ANORECTUM. WITH HEAVILY UPGRADED HARDWARE, SOFTWARE AND GRAPHICAL USER INTERFACE, THE NEW FECOBIONICS DEVICE MAP THE GEOMETRIC PROFILES DURING EVACUATION AND RELATE THEM TO SIMULTANEOUS CHANGES IN PRESSURES (FORCES) AND BENDING. OUR CENTRAL HYPOTHESIS IS THAT THE MOVEMENT OF THE FECOBIONICS DEVICE THROUGH THE ANORECTUM WILL PROVIDE UNKNOWN AND NEW MECHANISTIC INSIGHTS ON ANORECTAL PHYSIOLOGY INCLUDING INTRALUMINAL PRESSURE CHANGES, ANAL MUSCLE LENGTH-TENSION RELATIONS, RESISTANCE GENERATED DURING MOVEMENT OF THE SURROGATE STOOL AND ITS DEFORMABILITY, AS WELL AS DISTENSIBILITY OF THE ANAL SPHINCTERS IN NORMAL SUBJECTS AND FI PATIENTS. THIS MULTIDIMENSIONAL DATA COULD FACILITATE NEW TREATMENTS FOR FI. ACCORDINGLY, OUR SPECIFIC AIMS ARE TO: 1) DETERMINE THE LENGTH-TENSION PROPERTIES OF THE ANAL SPHINCTERS USING FECOBIONICS IN NORMAL SUBJECTS AND FI PATIENTS DURING ANAL DISTENSION AND DURING SIMULATED EVACUATION. 2) ELUCIDATE THE PATHOPHYSIOLOGICAL CHARACTERISTICS AND BIOMECHANICAL PROPERTIES OF INDIVIDUAL MUSCLE COMPONENTS, EXTERNAL, INTERNAL ANAL SPHINCTER AND PUBORECTALIS MUSCLE USING THE FECOBIONICS DEVICE AND COMPARING FI PATIENTS WITH NORMAL SUBJECT CONTROLS; AND 3) EVALUATE THE USE OF FECOBIONICS AS A BIOFEEDBACK TREATMENT (BT) AND MONITORING TOOL IN FI PATIENTS TO DETERMINE THE PREDICTORS FOR TREATMENT SUCCESS, BY PERFORMING A RANDOMIZED CONTROLLED TRIAL OF FECOBIONICS-ASSISTED BIOFEEDBACK THERAPY (FBT) VERSUS CONVENTIONAL OFFICE-BASED BIOFEEDBACK THERAPY (OBT). OUR PROPOSAL SEEKS TO SHIFT CURRENT FI RESEARCH BY TESTING A STOOL SURROGATE FOR PERFORMING BT AS OPPOSED TO A THIN MANOMETRY PROBE AND EXAMINE THE MULTI-DIMENSIONAL PHYSIOLOGIC CHANGES (I.E., PRESSURE, DEFORMABILITY, BIOMECHANICS, VECTORAL AND TOPOGRAPHIC CHANGES) AS WELL AS CLINICAL OUTCOME FOLLOWING BT. THE UNIQUE ASPECT OF OUR PROPOSAL IS TO SIMULATE STOOLING WITH A WIRELESS BIONICS DEVICE AND EXAMINE IN DETAIL THE MECHANISTIC UNDERPINNINGS IN HEALTH AND IN FI PATIENTS. THE IMPACT OF OUR PROJECT IS TO PROVIDE NEW MECHANISTIC UNDERSTANDING OF ANORECTAL FUNCTION AND PATHOPHYSIOLOGY IN FI AND VALIDATE THE CLINICAL UTILITY OF A NOVEL, HIGHLY INTEGRATED DEVICE FOR DIAGNOSTICS AND FACILITATION OF BIOFEEDBACK THERAPY WITH AN UNPRECEDENTED GRAPHICAL FEEDBACK TO THE PATIENT OF MECHANOSENSORY ACTIONS.$523.0K
R01DK125657↗Department of Health and Human ServicesTHE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INCPROJECT GRANT (B)2026-05-262026-05-261DEFECATION MECHANISMS AND SUBTYPING OF CONSTIPATION PATIENTS WITH FECOBIONICS - ABSTRACT CHRONIC CONSTIPATION (CC) IS A COMMON CONDITION THAT AFFECTS UP TO 25% OF THE POPULATION IN NORTH AMERICA WITH RISING INCIDENCE THAT POSES A MAJOR BURDEN ON THE HEALTHCARE COST. THE PATHOPHYSIOLOGY OF THIS CONDITION IS POORLY UNDERSTOOD AND CONSEQUENTLY THERE ARE INADEQUATE TREATMENTS. THE SIGNIFICANT PROBLEMS ARE, 1) INCOMPLETE UNDERSTANDING OF THE DEFECATION REFLEX AND 2) LACK OF PHYSIOLOGICALLY RELEVANT AND PRACTICAL DIAGNOSTIC TEST FOR IDENTIFYING THE UNDERLYING MECHANISM(S). CURRENT DIAGNOSTIC TESTS PROVIDE INCOMPLETE AND OFTEN CONFLICTING INFORMATION. NOT SURPRISINGLY, RESULTS OF THESE TESTS CORRELATE POORLY WITH SYMPTOMS AND TREATMENT OUTCOMES. OUR OBJECTIVE IS TO PROVIDE AN IMPROVED UNDERSTANDING OF THE CONTINENCE MECHANISMS AND DEFECATION PATTERNS IN HEALTHY SUBJECTS AND PATIENTS WITH CC USING A NOVEL FECOBIONICS DEVICE FOR MAPPING THE GEOMETRIC AND MANOMETRIC PROFILES DURING EVACUATION. FECOBIONICS IS AN ELECTRONIC SIMULATED STOOL THAT HAS THE CONSISTENCY AND SHAPE OF NORMAL STOOL. THE DEVICE RECORDS PRESSURES, CROSS-SECTIONAL AREA, ORIENTATION, BENDING, SHAPE, AND VISCOELASTIC PROPERTIES OF THE RECTUM AND ANAL CANAL SIMULTANEOUSLY. OUR CENTRAL HYPOTHESIS IS THAT RECTAL PERISTALSIS IS A KEY COMPONENT OF THE DEFECATORY REFLEX WHICH IS NOT ASSESSED IN THE CURRENT PARADIGM OF DIAGNOSTIC TESTING. THE NOVEL FECOBIONICS DEVICE WILL MIMIC THE NATURAL DEFECATION AND PROVIDE NEW MECHANISTIC INSIGHTS INTO THE ANORECTAL PHYSIOLOGY AND PATHOPHYSIOLOGY TO FACILITATE THE DEVELOPMENT OF NEW TREATMENTS FOR CC. FECOBIONICS CAN PROVIDE COMPLETE PICTURE OF THE NORMAL DEFECATION PATTERN (“SIGNATURES”) THAT INCLUDES RECTAL PERISTALTIC REFLEX, DEFORMABILITY OF THE DEVICE AND DISTENSIBILITY OF THE ANAL SPHINCTERS IN HEALTHY SUBJECTS AND PATIENTS WITH VARIOUS SUBTYPES OF CC. THE SPECIFIC AIMS ARE AS FOLLOWS: 1) STUDY THE DEFECATION DYNAMICS IN NORMAL CONTROL SUBJECTS USING FECOBIONICS. WE WILL ESTABLISH THE ROLE OF RECTAL CONTRACTION/PERISTALSIS IN THE NORMAL EVACUATION PROCESS. 2) DEFINE THE DEFECATORY PATTERNS IN PATIENTS WITH CC ASSOCIATED WITH DEFECATORY DISORDERS. WE WILL DETERMINE IF ABNORMALITIES OF RECTAL CONTRACTION CONTRIBUTE TO THE CC. 3) USE A MATHEMATICAL MODEL OF ANORECTAL PASSAGE OF FECOBIONICS FOR ENHANCED UNDERSTANDING OF THE NORMAL AND ABNORMAL DEFECATORY PATTERNS, INCLUDING THE LENGTH-TENSION PROPERTIES OF THE RECTUM AND ANAL SPHINCTER MUSCLES. OUR PROPOSAL SEEKS TO SHIFT CURRENT CC RESEARCH BY PROVIDING A STOOL SURROGATE FOR EXAMINING THE PHYSIOLOGIC PARAMETERS OF DEFECATION REFLEX USING A NOVEL DEVICE THAT WILL RECORD, PRESSURE, DEFORMABILITY, BIOMECHANICS, VECTORAL AND TOPOGRAPHIC CHANGES IN THE RECTUM AND ANAL CANAL. THE NOTED PARAMETERS WILL BE RECORDED USING A WIRELESS FECOBIONICS DEVICE THAT CAN EXAMINE IN DETAIL THE MECHANISTIC UNDERPINNINGS (STRESS AND DEFORMATION) OF DEFECATION REFLEX/PROCESS IN HEALTH AND DISEASE. THE IMPACT OF THIS PROJECT IS THAT IT ASSESSES A NOVEL, SAFE, LOW COST, LESS INVASIVE, LOW-RISK, RADIATION-FREE DEVICE IN ITS ABILITY TO PROVIDE BETTER UNDERSTANDING OF EVACUATION AND CONTINENCE MECHANISMS AND THEREBY FACILITATE FUTURE DEVELOPMENT OF INNOVATIVE THERAPIES. THE IMPROVEMENT CAN LEAD TO IMPROVEMENT IN DIAGNOSTIC AND THERAPEUTIC MODALITIES AND REDUCE HEALTHCARE COSTS ASSOCIATED WITH ANORECTAL DISORDERS.$0
R01DK134689↗Department of Health and Human ServicesTHE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INCPROJECT GRANT (B)2026-06-252026-06-251FECOBIONICS MONITORING AND PREDICTION OF BIOFEEDBACK THERAPY OUTCOME IN PATIENTS WITH OBSTRUCTED DEFECATION. - ABSTRACT DEFECATORY DISORDERS AFFECT 25% OF THE POPULATION AND THEY ARE POORLY RECOGNIZED AND TREATED. THE INCIDENCE OF DEFECATORY DISORDERS INCLUDING CHRONIC CONSTIPATION IS RISING AND IT POSES A MAJOR HEALTHCARE BURDEN. THE UNDERLYING MECHANISMS FOR THESE DISORDERS ARE OFTEN NOT WELL UNDERSTOOD. OBSTRUCTED DEFECATION (DYSSYNERGIA) HAS SEVERAL CAUSES AND IS SUBDIVIDED IN FOUR SUBTYPES. DESPITE THE HIGH PREVALENCE AND INCIDENCE, DIAGNOSTICS AND TREATMENT OPTIONS ARE SPARSE. A SIGNIFICANT PROBLEM IN ANORECTAL PHYSIOLOGY TESTING IS A LACK OF PHYSIOLOGICALLY RELEVANT AND PRACTICAL DIAGNOSTIC TEST FOR IDENTIFYING THE UNDERLYING MECHANISMS TO IDENTIFY PROPER TREATMENT. CURRENT DIAGNOSTIC TESTS PROVIDE INCOMPLETE AND OFTEN CONFLICTING INFORMATION BECAUSE THEY DO NOT SIMULATE FECES OR THE DEFECATION PROCESS. NOT SURPRISINGLY, RESULTS OF THESE TESTS CORRELATE POORLY WITH SYMPTOMS AND TREATMENT OUTCOMES. BIOFEEDBACK THERAPY IS A WELL-ESTABLISHED THERAPY FOR OBSTRUCTED DEFECATION BUT DESPITE THE SUBSTANTIAL POTENTIAL AND PROMISING RESULTS, BIOFEEDBACK THERAPY IS ONLY DONE AT SPECIALIZED CENTERS AND SHOULD BE ADVANCED CLOSER TO THE POINT OF CARE. THE OBJECTIVE OF THIS SMALL R01 PROPOSAL IS TO MONITOR AND PREDICT THE OUTCOME OF BIOFEEDBACK THERAPY BASED ON UNPRECEDENTED INTEGRATED VISUAL FEEDBACK FROM THE NOVEL SIMULATED FECES DEVICE TERMED FECOBIONICS. THE DEVICE IS ELECTRONIC SIMULATED FECES THAT HAS THE CONSISTENCY AND SHAPE OF NORMAL STOOL. FECOBIONICS WILL PROVIDE MECHANISTIC UNDERSTANDING OF DEFECATION FOR THE EXAMINER BY VISUALIZING THE GEOMETRIC (CROSS-SECTIONAL AREA, BENDING AND SHAPE OF DEVICE) AND MANOMETRIC PROFILES OF THE SIMULATED FECES BEFORE AND DURING DEFECATION. THE CENTRAL HYPOTHESIS IS THAT THE FECOBIONICS DEVICE THAT MIMICS NATURAL DYNAMIC DEFECATION PROVIDES VALID DATA ON RECTAL EMPTYING ATTEMPTS FOR THE VARIOUS COMPONENTS OF THE DEFECATORY SYSTEM SUCH AS THE TONE OF ANAL SPHINCTERS AND PUBORECTALIS MUSCLE, AND ON MECHANOSENSORY PROPERTIES. THE OBJECTIVE IS TO MONITOR AND PREDICT BIOFEEDBACK THERAPY BASED ON MECHANISM-BASED AND HIGHLY INTEGRATED DATA THAT CAN BE VISUALIZED DURING ANORECTAL NEUROMUSCULAR EXERCISES. FOR THE PROPOSED STUDIES, WE WILL SELECT DYSSYNERGIA PATIENTS, WHO WILL BE MONITORED WITH FECOBIONICS BEFORE, DURING AND AFTER BIOFEEDBACK THERAPY. THE HYPOTHESIS IS FECOBIONICS DATA WILL CORRELATE BETTER TO SYMPTOMS BASED ON CONSTIPATION SCORES THAN CONVENTIONAL TECHNOLOGIES AND THAT SUCH DATA CAN BE USED TO PREDICT RESPONDERS AND NON-RESPONDERS TO THERAPY. OUR PROPOSAL SEEKS TO SHIFT CURRENT RESEARCH IN CONSTIPATION THERAPY BY USE OF A NOVEL DEVICE THAT PROVIDES MECHANISTIC INSIGHTS BY SIMULATING DEFECATION PATHOPHYSIOLOGICALLY AND EXAMINING THE MECHANISTIC CHANGES MULTI-DIMENSIONALLY: PRESSURE, DEFORMABILITY, BIOMECHANICS, AND TOPOGRAPHIC CHANGES TO MONITOR UNDERLYING DEFECTS IN PATIENTS WITH OBSTRUCTED DEFECATION, ESPECIALLY IN DYSSYNERGIA. THE UNIQUE ASPECTS OF OUR PROPOSAL ARE TO SIMULATE STOOL WITH A BIONICS DEVICE THAT INTEGRATES MULTIPLE VARIABLES THAT EXAMINE THE MECHANISTIC UNDERPINNINGS OF OBSTRUCTED DEFECATION. THE IMPACT OF THIS PROJECT IS TO SHED NEW UNDERSTANDING OF CONSTIPATION AND TO PREDICT RESPONDERS. THIS WILL FACILITATE DEVELOPMENT OF INNOVATIVE BOWEL MANAGEMENT PROGRAMS USING FECOBIONICS AS THE BIOFEEDBACK THERAPY TOOL.$0
Why this number?
  • Amounts are obligations (money committed), not outlays (money paid).
  • Company roll-ups match names and parent companies; some subsidiaries may be missed.
  • Matched: CSLYY6VAHXX7 → THE CALIFORNIA MEDICAL INNOVATIONS INSTITUTE, INC
  • Amounts are the award's obligations within the selected years, not its lifetime value.
  1. Source USAspending.gov prime awards · about the data

Open as a question →

SAM.gov registration

  • UEI CSLYY6VAHXX7 · CAGE code 73DP4
  • Federal assistance only · SAN DIEGO, CA
  • Registered since 2014-04-02; expires 2027-10-06
  • In business since 2014-01-01
  • Nonprofit

Red flags

No SAM.gov exclusion (debarment or suspension) and no single-audit findings on file for any of its registrations.

SAM.gov exclusions and the Federal Audit Clearinghouse (audits partly loaded).

From public government records, which may contain errors. Check the official source before relying on a number. Not financial, legal or investment advice. Terms · About the data

Download CSV of the summary: money by year, top agencies, industries, states and largest awards

Ask the AI chat about this company →