| U44NS114420↗ | Department of Health and Human Services | BIOCIRCUIT TECHNOLOGIES INC | COOPERATIVE AGREEMENT (B) | 2026-05-05 | 2026-09-03 | 2 | SPINAL REFLEX CONDITIONING SYSTEM FOR ENHANCING MOTOR FUNCTION RECOVERY AFTER INCOMPLETE SPINAL CORD INJURY - PROJECT SUMMARY HOFFMANN REFLEX (H-REFLEX (HR)) OPERANT CONDITIONING (HROC) HAS EMERGED AS AN IMPORTANT NEW NEUROREHABILITATION THERAPY THAT CAN ENHANCE RECOVERY OF FUNCTION FOR PEOPLE WITH SPINAL CORD INJURY, STROKE, MULTIPLE SCLEROSIS, AND OTHER CHRONIC DISORDERS. THIS U44 GRANT HAS DEVELOPED A COMPACT HROC SYSTEM, CURRENTLY CALLED “POLARIS,” THAT IS SUITABLE FOR WIDESPREAD DISSEMINATION TO AND USE BY CLINICAL THERAPISTS. POLARIS SIMPLIFIES AND AUTOMATES MUCH OF THE CONDITIONING PROCESS SO THAT IT CAN BE READILY MASTERED AND ADMINISTERED BY CONSCIENTIOUS CLINICAL THERAPISTS. THIS NEW SYSTEM IS CURRENTLY PERFORMING VERY WELL IN THE CLINICAL TRIAL PORTION OF THE U44 GRANT. THE HROC THERAPEUTIC PROTOCOL IMPLEMENTED BY POLARIS ENTAILS 36 ONE-HR SESSIONS AT A RATE OF 3/WEEK OVER 12 WEEKS. THE TIME AND EFFORT REQUIRED ARE CONSIDERABLE, BOTH FOR THE PATIENT AND FOR THE THERAPIST. FURTHERMORE, THIS REQUIREMENT IS LIKELY TO MAKE CMS/PRIVATE INSURANCE REIMBURSEMENT MORE DIFFICULT TO OBTAIN. TO ADDRESS THIS ISSUE, WE HAVE OVER THE PAST YEAR COMPLETED A STUDY THAT ASSESSED WHETHER IT IS POSSIBLE TO SUBSTANTIALLY REDUCE THE NUMBER OF HROC SESSIONS BY INCREASING THE NUMBER OF HROC TRIALS IN EACH SESSION. IN SHORT, HROC IS TYPICALLY PERFORMED WITH STIMULI DELIVERED EVERY 5 SECONDS IN ORDER TO AVOID RATE-DEPENDENT DEPRESSION (RDD). THE RECENTLY COMPLETED STUDY EVALUATED RDD IN HEALTHY SUBJECTS AT HIGHER STIMULATION RATES AND FOUND THAT STIMULATION AT UP TO ONE STIMULUS PER SECOND DID NOT LEAD TO RDD IN STANDING SUBJECTS. THIS IMPLIES THAT STIMULI COULD BE DELIVERED AT FIVE TIMES THE ORIGINAL RATE, WHICH WOULD SUBSTANTIALLY REDUCE THE AMOUNT OF TIME REQUIRED TO PERFORM THE FULL THERAPEUTIC PROTOCOL. THE EXCITING RESULTS OF THIS STUDY ARE THE REASON FOR THIS ADMINISTRATIVE SUPPLEMENT REQUEST. WE NOW NEED TO CONDUCT A SMALL STUDY TO VERIFY THAT THE INCREASED HR ELICITATION RATE PROVIDES HROC AT LEAST COMPARABLE TO (AND POSSIBLY BETTER THAN) THE HROC PROVIDED BY THE CURRENT SLOW RATE. THIS STUDY WOULD ALSO ASSESS THE EXTENT TO WHICH THE GREATER RATE REDUCES THE NUMBER OF HROC SESSIONS NEEDED. TO ADDRESS THESE QUESTIONS, WE PROPOSE TO TEST THE NEW 1-HZ HROC PROTOCOL IN 10 PEOPLE WITH SPASTICITY DUE TO CHRONIC SPINAL CORD INJURY OR STROKE. WE WOULD CONDUCT THIS STUDY OVER THE NEXT 18 MONTHS IN DRS. WOLPAW’S AND HILL’S CLINICAL LAB AT THE ALBANY STRATTON VA MEDICAL CENTER. THUS, IT WOULD NOT AFFECT THE U44 CLINICAL TRIAL NOW ONGOING AT DR. THOMPSON’S LAB IN CHARLESTON. IN SUM, THIS SUPPLEMENT PROJECT WOULD SUBSTANTIALLY ENHANCE THE YIELD OF OUR U44 GRANT. AT PRESENT, THE GRANT WILL PRODUCE A CLINICALLY PRACTICAL HROC SYSTEM SUITABLE FOR COMMERCIALIZATION AND WIDESPREAD CLINICAL USE. THE WORK PROPOSED FOR THIS ADMINISTRATIVE SUPPLEMENT WOULD INCREASE THE PATIENT POPULATION THAT COULD RECEIVE THIS THERAPY, DECREASE PATIENT AND THERAPIST EFFORT AND EXPENSE, AND FACILITATE APPROVAL OF CMS/PRIVATE INSURANCE REIMBURSEMENT. THESE EFFECTS WOULD SIGNIFICANTLY ENHANCE THE ULTIMATE CLINICAL BENEFITS OF OUR GRANT. THE PROJECT SUMMARY IS A SUCCINCT AND ACCURATE DESCRIPTION OF THE PROPOSED WORK AND SHOULD BE ABLE TO STAND ON ITS OWN (SEPARATE FROM THE APPLICATION). THIS SECTION SHOULD BE INFORMATIVE TO OTHER PERSONS WORKING IN THE SAME OR RELATED FIELDS AND UNDERSTANDABLE TO A SCIENTIFICALLY LITERATE READER. AVOID BOTH DESCRIPTIONS OF PAST ACCOMPLISHMENTS AND THE USE OF THE FIRST PERSON. PLEASE BE CONCISE. FORMAT: THIS SECTION IS LIMITED TO 30 LINES OF TEXT, AND MUST FOLLOW THE REQUIRED FONT AND MARGIN SPECIFICATIONS. A SUMMARY THAT EXCEEDS THE 30-LINE LIMIT WILL BE FLAGGED AS AN ERROR BY THE AGENCY UPON SUBMISSION. ATTACH THIS INFORMATION AS A PDF FILE. SEE THE FORMAT ATTACHMENTS PAGE. CONTENT: STATE THE APPLICATION'S BROAD, LONG-TERM OBJECTIVES AND SPECIFIC AIMS, MAKING REFERENCE TO THE HEALTH RELATEDNESS OF THE PROJECT (I.E., RELEVANCE TO THE MISSION OF THE AGENCY). DESCRIBE THE RESEARCH DESIGN AND METHODS FOR ACHIEVING THE STATED GOALS. BE SURE THAT THE PRO | $1.12M |
| R44NS097113↗ | Department of Health and Human Services | BIOCIRCUIT TECHNOLOGIES INC | PROJECT GRANT (B) | 2026-08-26 | 2026-08-26 | 1 | LINE EXTENSION AND EXPANDED PRECLINICAL EVIDENCE FOR NERVE TAPE, A SUTURELESS NERVE REPAIR COAPTATION DEVICE - PROJECT SUMMARY BIOCIRCUIT TECHNOLOGIES’ NERVE TAPE® IS A BIOLOGIC WRAP WITH INTEGRATED MICROHOOKS FOR SUTURELESS REPAIR OF INJURED NERVES. THIS SBIR PHASE IIB PROJECT COMPRISES ACTIVITIES CRITICAL FOR PROMOTING ADOPTION OF NERVE TAPE UPON COMMERCIAL LAUNCH. NERVE INJURIES ARE COMMON AND RESULT IN PARALYSIS, SENSORY LOSS, AND CHRONIC PAIN. IN CURRENT REPAIR TECHNIQUES, THE ENDS OF A CUT NERVE ARE MICROSUTURED BACK TOGETHER UNDER HIGH MAGNIFICATION BY A SPECIALIZED SURGEON. MICROSUTURE REPAIR TECHNIQUES ARE TECHNICALLY CHALLENGING AND TIME INTENSIVE, AND REPAIR QUALITY IS NOT CONSISTENT. NERVE TAPE WAS DEVELOPED AS A SIMPLE AND EASY-TO-USE ALTERNATIVE TO MICROSUTURE REPAIR. THE DEVICE CONSISTS OF FLEXIBLE COLUMNS OF MICROSCALE NITINOL HOOKS EMBEDDED IN A BIOLOGIC WRAP. THE DEVICE EASILY WRAPS TO ALIGN AND HOLD TOGETHER THE TWO ENDS OF A SEVERED NERVE. THE MICROHOOKS ARE DESIGNED FOR SAFE, SHALLOW PENETRATION INTO OUTER CONNECTIVE TISSUE LAYERS OF THE NERVE, EVENLY DISTRIBUTING TENSION FOR A FIRM HOLD. NERVE TAPE IS EASILY AND QUICKLY APPLIED, RELIABLY AND SAFELY ALIGNING NERVE ENDS FOR CONSISTENT, HIGH-QUALITY REPAIRS. TO PROMOTE ADOPTION OF NERVE TAPE UPON COMMERCIAL LAUNCH, THE PROPOSED WORK WILL 1) EXTEND THE SIZE RANGE OF THE DEVICE FOR GREATER MARKET CAPTURE AND 2) GATHER KEY PRECLINICAL DATA TO GUIDE SURGEON PERCEPTION AND SUPPORT KEY MARKETING CLAIMS. TO ADDRESS COMMONLY INJURED NERVES SUCH AS SMALL DIGITAL, FACIAL, AND BRANCHED MOTOR NERVES, THE NERVE TAPE SIZE RANGE WILL BE EXPANDED TO INCLUDE 1-2MM NERVE DIAMETERS. ADDITION OF THE NEW SIZE REQUIRES DESIGN OPTIMIZATION AND SUBSEQUENT VERIFICATION AND VALIDATION TESTING TO SUPPORT REGULATORY CLEARANCE OF THE SMALLER SIZED DEVICE. SEPARATELY, PERFORMANCE DATA IN SPECIFIC SCENARIOS WILL BE COLLECTED TO PROACTIVELY DISPEL PERCEIVED CLINICIAN CONCERNS THAT MIGHT HINDER ADOPTION. SPECIFICALLY, NERVE TAPE’S PERFORMANCE WILL BE DEMONSTRATED IN AREAS OF FLEXION (USING A RABBIT KNEE FLEXION MODEL) AND IN LONG-TERM IMPLANT SCENARIOS (USING A 9-MO. PIG MODEL). FINALLY, WE WILL GATHER EVIDENCE OF NERVE TAPE’S SUPERIOR EFFICIENCY AND REPAIR QUALITY CONSISTENCY. THESE ADVANTAGES WILL BE DEMONSTRATED THROUGH A RABBIT TRANSECTED NERVE REPAIR STUDY COMPARING SURGICAL TIME AND REGENERATION OUTCOMES ACHIEVED BY SURGEONS OF VARIED MICROSURGERY EXPERIENCE USING NERVE TAPE OR CONVENTIONAL MICROSUTURE-BASED REPAIR. THE STEPS PROPOSED IN THIS PROJECT WILL POSITION NERVE TAPE FOR MAXIMAL MARKET PENETRATION AFTER COMMERCIAL LAUNCH, ENABLING WIDESPREAD ADOPTION AS A NERVE REPAIR DEVICE THAT REDUCES SURGICAL TIME AND COMPLEXITY FOR CONSISTENT, HIGH-QUALITY REPAIRS AND IMPROVED RECOVERY OUTCOMES. | $777.6K |
| R43HL184714↗ | Department of Health and Human Services | BIOCIRCUIT TECHNOLOGIES INC | PROJECT GRANT (B) | 2026-08-10 | 2026-08-10 | 1 | LYMPH TAPE: A DEVICE FOR SIMPLIFIED LYMPHOVENOUS ANASTOMOSIS - PROJECT SUMMARY LYMPHEDEMA IS A PROGRESSIVE AND DEBILITATING CONDITION AFFLICTING OVER 10 MILLION AMERICANS. CURRENT SURGICAL TREATMENTS ARE EXTREMELY TIME DEMANDING AND SKILL INTENSIVE. THE PROPOSED PROJECT WILL OPTIMIZE AND VALIDATE A MICROHOOK-BASED DEVICE FOR QUICK AND EFFECTIVE LYMPHOVENOUS ANASTOMOSIS (LVA) FOR THE PREVENTION AND TREATMENT OF LYMPHEDEMA. “LYMPH TAPE” CONSISTS OF A FLEXIBLE BIOLOGIC WRAP CONTAINING MICROSCALE HOOKS, WHICH SAFELY ENGAGE AND HOLD THE OUTER CONNECTIVE TISSUE OF LYMPHATIC VESSELS AND VEINS. LYMPH TAPE WILL SIMPLIFY THE LVA PROCEDURE BY COUPLING A LYMPHATIC VESSEL TO A VEIN THROUGH AN EASY AND INTUITIVE WRAPPING TECHNIQUE THAT DOES NOT REQUIRE MICROSUTURES, SPECIALIZED TOOLS, OR “SUPER MICROSURGICAL TECHNIQUE”. THE SHORT MICROHOOKS PENETRATE ONLY INTO THE OUTER, CONNECTIVE TISSUE LAYERS OF THE VESSELS, FORMING AN EFFECTIVE MECHANICAL CONNECTION THAT IS AKIN TO VELCROTM BRAND PRODUCTS, BUT SAFELY REVERSIBLE. THE DEVICE CAN BE APPLIED QUICKLY AND REPRODUCIBLY FOR A STRONG AND FLUID-TIGHT SEAL. VERSUS THE CURRENT CLINICAL STANDARD MICROSUTURE REPAIR, LYMPH TAPE HAS THE POTENTIAL TO REDUCE OVERALL SURGICAL COSTS AND COMPLEXITY TO ENHANCE PATIENT ACCESS TO EFFECTIVE LYMPHEDEMA TREATMENT. THIS PROPOSED PHASE I PROJECT WILL OPTIMIZE THE LYMPH TAPE’S DESIGN AND VALIDATE ITS EFFICACY IN ACUTE SETTINGS. SPECIFICALLY, AIM 1 WILL TEST VARIOUS GEOMETRIES AND PATTERNS OF MICROHOOKS, WHILE AIM 2 OPTIMIZES THE WRAPPING MATERIAL CONFIGURATION AND POTENTIAL CLOSURE MECHANISMS. AIM 3 WILL VALIDATE DEVICE USABILITY AND PERFORMANCE IN COMPARISON WITH STANDARD MICROSUTURE TECHNIQUES, THROUGH A CONTROLLED CADAVER STUDY DIRECTED BY OUR PARTNER MICROSURGEON. PHASE II WILL INCLUDE EXTENSIVE ANIMAL SAFETY AND EFFICACY TESTING, REGULATORY DEVELOPMENT, ESTABLISHMENT OF MANUFACTURING PROCESSES, AND ULTIMATELY 510K APPROVAL AND LICENSING/DISTRIBUTION AGREEMENTS. THE FINAL PRODUCT WILL BE AN FDA-APPROVED DEVICE THAT CAN BE STORED ON THE SHELF FOR USE DURING LVA PROCEDURES. LYMPH TAPE WILL REDUCE HEALTHCARE COSTS WHILE IMPROVING PATIENT ACCESS AND QUALITY OF RECOVERY FROM LYMPHEDEMA, A DEBILITATING AND UNDERTREATED CONDITION. | $379.2K |
| HR001126CE048↗ | Department of Defense | BIOCIRCUIT TECHNOLOGIES INC | DEFINITIVE CONTRACT | 2026-01-27 | 2026-07-22 | 2 | DARPA COMMERCIAL SOLUTIONS OPENING - EMBEDDED ENTREPRENEUR INITIATIVE | $350.0K |
| SB1NS137879↗ | Department of Health and Human Services | BIOCIRCUIT TECHNOLOGIES INC | PROJECT GRANT (B) | 2026-05-12 | 2026-05-12 | 1 | COMMERCIALIZATION READINESS FOR NERVE TAPE: A NERVE REPAIR COAPTATION AID - PROJECT SUMMARY THIS SBIR COMMERCIALIZATION READINESS PILOT PROJECT WILL PREPARE AND ACHIEVE THE COMMERCIAL LAUNCH OF BIO- CIRCUIT TECHNOLOGIES’ NERVE TAPE® DEVICE FOR SUTURELESS NERVE REPAIR. NERVE INJURIES ARE COMMON AND RESULT IN PARALYSIS, SENSORY LOSS, AND CHRONIC PAIN. IN CURRENT REPAIR TECHNIQUES, THE ENDS OF A CUT NERVE ARE MICROSUTURED BACK TOGETHER UNDER HIGH MAGNIFICATION BY A SPECIALIZED SURGEON. MICROSUTURE REPAIR TECHNIQUES ARE TECHNICALLY CHALLENGING AND TIME INTENSIVE, AND REPAIR QUALITY IS NOT CONSISTENT. NERVE TAPE WAS DEVELOPED AS A SIMPLE AND EASY-TO-USE ALTERNATIVE TO MICROSUTURE REPAIR. NERVE TAPE CONSISTS OF FLEXIBLE COLUMNS OF MICROSCALE NITINOL HOOKS EMBEDDED IN A BIOLOGIC WRAP. THE DEVICE EASILY WRAPS TO ALIGN AND HOLD TOGETHER THE TWO ENDS OF A SEVERED NERVE. THE MICROHOOKS ARE DESIGNED FOR SAFE, SHALLOW PENETRATION INTO OUTER CONNECTIVE TISSUE LAYERS OF THE NERVE, EVENLY DISTRIBUTING TENSION FOR A FIRM HOLD. NERVE TAPE IS EASILY AND QUICKLY APPLIED, RELIABLY AND SAFELY ALIGNING NERVE ENDS FOR HIGH-QUALITY REPAIRS. TO ACHIEVE INITIAL COMMERCIALIZATION LAUNCH OF THE NERVE TAPE PRODUCT, BIOCIRCUIT MUST COMPLETE SEVERAL KEY STEPS. A STRATEGIC SWITCH IN THE 510(K) CLEARED DEVICE TO A NEW BIOLOGIC MATERIAL SUPPLIER REQUIRES SOME VERIFICATION AND VALIDATION TESTING STEPS TO BE REPEATED. THIS TESTING WILL SUPPORT A NEW REGULATORY SUBMISSION TO GAIN CLEARANCE FOR THE UPDATED DEVICE. PRIOR TO PRODUCTION OF DEVICES FOR CLINICAL USE, A FORMAL DESIGN TRANSFER PROCESS MUST BE COMPLETED. THIS PROCESS INCLUDES ENSURING ALL VENDORS AND SUPPLIERS ARE CERTIFIED AND/OR QUALIFIED, AND ALL SUPPLIER AGREEMENTS ARE IN PLACE. TOOLING FOR FABRICATING THE FULL RANGE OF DEVICE SIZES MUST ALSO BE BUILT AND QUALIFIED. MANUFACTURING PROCESSES THAT WERE PREVIOUSLY DEVELOPED AND REFINED MUST NOW BE TRANSFERRED TO A CERTIFIED CONTRACT MANUFACTURER, AND ALL PRODUCTION PROCESSES MUST TO BE QUALIFIED TO MEET PRODUCT SPECIFICATIONS. AFTER COMPLETING THE DESIGN TRANSFER PROCESS AND DOCUMENTING THIS PROCESS IN BIOCIRCUIT’S QUALITY MANAGEMENT SYSTEM, PRODUCTION RUNS WILL BUILD ENOUGH DEVICES TO SUPPORT AN INITIAL COMMERCIAL LAUNCH PHASE. TO PREPARE FOR SUCCESSFUL COMMERCIAL LAUNCH, MARKET RESEARCH AND ANALYTICS WILL GUIDE PLANS FOR INITIAL LAUNCH AND SUBSEQUENT GROWTH. CLINICAL AFFAIRS ACTIVITIES WILL INCLUDE PLANS FOR GATHERING EVIDENCE TO SUPPORT KEY CLAIMS AND PREPARATIONS FOR A CLINICAL REGISTRY AS PART OF A BROADER EVIDENCE STRATEGY. A STRATEGICALLY LIMITED “SOFT LAUNCH” WILL BE CONDUCTED AT SELECT ACCOUNTS TO ESTABLISH AND OPTIMIZE COMMERCIAL PROCEDURES, OBTAIN CLINICAL FEEDBACK, AND POSITION NERVE TAPE FOR MARKET PENETRATION FOLLOWING FULL LAUNCH. DUE TO ITS SIMPLE, EFFICIENT, AND RELIABLE USAGE, NERVE TAPE WILL BE AN ATTRACTIVE TOOL FOR SURGEONS AND COULD EXPAND FUTURE TREATMENT STRATEGIES FOR NERVE REPAIR. | $240.1K |