R01GM143626↗

Adamas Nanotechnologies, Inc. received this grant or assistance award from National Institutes of Health: $1.00M obligated so far for biomedical research and research training. Its latest action was on 2026-05-04.

Key facts · data as of Nov 20, 2026

Recipient
Adamas Nanotechnologies, Inc.
Awarding agency
National Institutes of Health (Department of Health and Human Services)
Obligated to date
$1.00M

Source: USAspending.gov prime award records (obligations: money committed, not outlays), data as of Nov 20, 2026.

Cite this page: SpendQuery, Award R01GM143626, data as of Nov 20, 2026, https://spendquery.com/award?id=ASST_NON_R01GM143626_075

PHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING IS A WORKHORSE TECHNIQUE FOR THE CELLULAR IMAGING OF BIOLOGICAL MOLECULAR MARKERS, IT SUFFERS FROM LIGHT SCATTERING, AND ABERRATION DISTORTIONS AT TISSUE DEPTHS >1 MM. ON THE OPPOSITE END OF THE SPECTRUM, MAG- NETIC RESONANCE IMAGING (MRI) IS A WELL-ESTABLISHED AND BROADLY EMPLOYED PRE-CLINICAL AND CLINICAL IMAGING METHOD THAT HAS NO PRACTICAL LIMITATIONS WITH RESPECT TO TISSUE DEPTH, BUT IT SUFFERS FROM LOW RESOLUTION. IN THIS PROJECT WE WILL INNOVATE A NEW CLASS OF HYPERPOLARIZED 13C NANOPARTICLE PROBES THAT CAN SERVE AS EFFICIENT DEEP TISSUE MARKERS IN MRI. OUR CENTRAL IDEA IS TO DRAMATICALLY BOOST 13C NMR SIGNAL BY MEANS OF (I) OPTICAL HYPERPO- LARIZATION THAT CAN BE CARRIED OUT AT LOW MAGNETIC FIELDS AND (II) SIGNIFICANT EXTENSION OF 13C COHERENCE TIMES. SPECIFICALLY, WE PROPOSE TO DEVELOP MRI PROBES BASED ON FLUORESCENT NANODIAMONDS (FNDS) ENDOWED WITH NITROGEN-VACANCY (NV) CENTERS. THE ELECTRONIC SPINS ASSOCIATED WITH NVS CAN BE OPTICALLY “HYPERPOLARIZED” AND THAT POLARIZATION TO BE EFFECTIVELY TRANSFERRED TO THE DIAMOND 13C NUCLEAR SPINS, RESULTING IN NMR SIGNAL ENHANCE- MENT OVER THREE ORDERS OF MAGNITUDE VS. 13C THERMAL POLARIZATION AT THE FIELDS OF CLINICAL MRI. IN CONJUNCTION, BY IMPLEMENTING EFFECTIVE DECOUPLING SCHEMES WE PROPOSE SIGNIFICANTLY EXTEND THE 13C SPIN COHERENCES TO BE ABLE TO INTERROGATE THEM FOR SECOND-LONG PERIODS. THE LATTER YIELDS ENORMOUS SIGNAL GAINS, A MULTIPLICATIVE FACTOR OF ANOTHER 103- FOLD. COMBINING THE GAINS DUE TO HYPERPOLARIZATION AND SPIN COHERENCE EXTENSIONS PERMITS A TOTAL SIGNAL GAIN OF CA. 106 FOR MRI, AND WILL ENABLE A SIGNIFICANT IMPROVEMENT IN SPATIAL RESOLUTION. MOREOVER, SINCE THE POLARIZATION IS OPTICALLY GENERATED, THIS 13C PHOTO-MRI (PMRI), CAN BE CARRIED OUT AT LOW-FIELD AT A MUCH LOWER COST VS. CONVENTIONAL MRI INFRASTRUCTURE. IN OUR METHOD THE SPIN POLARIZATION IS REGENERATED OPTICALLY, ALLOWING FOR ACQUIRING MRI DATA REPEATEDLY AND ENABLING LONGITUDINAL STUDIES. FURTHERMORE, THE FND PARTICLES ARE INHERENTLY BIOCOMPATIBLE, AND THEIR SURFACES ARE AMENABLE TO A VERSATILE SET OF TARGETING LIGANDS. WITH THIS BASIS, WE PROPOSE TO DEVELOP TARGETABLE FLUORESCENT NANOPARTICLE MRI PROBES THAT CAN BE IMAGED WITH HIGH FIDELITY WITH RESOLUTION BETTER THAN 20 UM IN DEEP TISSUE (>1 CM) SETTINGS. IN ADDITION TO BEING BRIGHT MRI AGENTS, THE PARTICLES ARE ALSO BRIGHT FLUORESCENT PROVIDING AN OPTION FOR A CROSS-EXAMINATION OF THE AGENT BIODISTRIBUTION IN HISTOPATHOLOGICAL ANALYSIS. IN ORDER TO REALIZE THE PROSPECTS OF THIS NOVEL TECHNOLOGY, WE PROPOSE TO FURTHER DEVELOP THE HYPERPO- LARIZATION AND MR IMAGING METHODOLOGIES, AS WELL AS BOOST HYPERPOLARIZABILITY OF NANOSIZED PARTICLES BY OPTIMIZ- ING THEIR STRUCTURE THROUGH SYNTHESIS AND PROCESSING DEVELOPMENTS. WE AIM AT TRANSFERRING THE PMRI TECHNOLOGY WE DEMONSTRATED FOR MICRON-SIZED PARTICLES TO THE NANOSIZED FND SUITABLE FOR IN VIVO MRI. AS A PART OF THE TECHNOLOGY DEMONSTRATION, WE WILL CONSTRUCT A SIMPLE PROTOTYPE PMRI IMAGING SET-UP ON THE BENCHTOP (LOW-FIELD) AND IMAGE FNDS IN TISSUE PHANTOMS, CHARACTERIZING ACHIEVABLE METRICS OF RESOLUTION AND IMAGING DEPTH.

Project Grant (B) · National Institutes of Health · to Adamas Nanotechnologies, Inc. (UEI XV1FPSTT7LF4) · data as of 2026-11-20

Obligated to date$1.00M6 actions
Period2023-04-25 → 2026-05-04first to last action

What it is

Program
Biomedical Research and Research Training (Assistance Listing 93.859)
Where the work is
Wake, NC · district NC-02

The research project

Photo-hyperpolarized 13C MRI · National Institute of General Medical Sciences (NIGMS) · led by OLGA A SHENDEROVA and 1 more, ADAMAS NANOTECHNOLOGIES, INC.

“High resolution imaging in deep tissue (> 1 cm) environments can address a swathe of funda- mental and applied problems in the elucidation of mechanisms of disease origin and progression.” Full abstract on RePORTER ↗

NIH research categories: Bioengineering · Biomedical Imaging · Nanotechnology

NIH funding by fiscal year: FY2022 $385.6K · FY2023 $337.2K · FY2024 $333.8K · FY2025 $332.8K ($1.39M in all) · project period 2022-09-28 to 2027-07-31.

Source: NIH RePORTER, project R01GM143626. RePORTER counts NIH's awards by year; USAspending's obligations above count each action.

Obligations by fiscal year

FY2023$337.2K
FY2024$333.8K
FY2025$332.8K
FY2026$0

SpendQuery holds FY2023 on; earlier years are on USAspending.gov.

Subrecipients: where the money went next

No subawards reported for this award. Primes report subawards of $30,000 or more; many awards have none.

Every action

6 actions since 2023-04-25. Each is a modification or amendment with the money it added or took back.

DateAmendmentKindAmountWhat the agency wrote
2026-05-04000Revision$0PHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING…
2025-09-19001Continuation$332.8KPHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING…
2025-09-16000Revision$0PHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING…
2024-09-17000Continuation$333.8KPHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING…
2023-09-06001Continuation$337.2KPHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING…
2023-04-25000Revision$0PHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING…

Source: USAspending.gov prime award transactions and FSRS subaward reports, as loaded by SpendQuery (data as of 2026-11-20). Amounts are obligations (money committed), not outlays. The official record on USAspending.gov ↗