| R43GM165231↗ | Department of Health and Human Services | ADAMAS NANOTECHNOLOGIES, INC. | PROJECT GRANT (B) | 2026-06-19 | 2026-06-19 | 1 | REAL-TIME MEASUREMENT OF MITOCHONDRIAL TEMPERATURE WITH FLUORESCENT NANODIAMOND - SUMMARY MITOCHONDRIA ARE CRITICALLY IMPORTANT CELL ORGANELLES COLLOQUIALLY REFERRED TO AS THE POWERHOUSES OF THE CELL. DYSFUNCTIONAL MITOCHONDRIA CAN EXHIBIT ALTERED BIOENERGETICS, WHICH CAN LEAD TO SYSTEMIC ISSUES IN HEALTH. FOR EXAMPLE, AGE RELATED DEGRADATION OF MITOCHONDRIA IS HYPOTHESIZED TO BE A CAUSE OF ALZHEIMER’S DISEASE. DYSFUNCTIONAL MITOCHONDRIA ARE ALSO IMPLICATED WITH DISEASES SUCH AS CANCER OR DIABETES. UNDERSTANDING THE METABOLIC STATE OF MITOCHONDRIA IS THUS AN IMPORTANT BIOMARKER OF HEALTH, AND MITOCHONDRIA ARE INCREASINGLY BEING INVESTIGATED AS THERAPEUTIC TARGETS. WHEN MITOCHONDRIA BECOME DYSFUNCTIONAL, THEY CAN EXHIBIT ALTERED BIOENERGETICS, AND THIS CAN MANIFEST WITH ALTERED HEAT PRODUCTION. HEAT CAN ACCOUNT FOR A LARGE AMOUNT OF THE ENERGY RELEASED BY MITOCHONDRIA AS THEY PRODUCE ATP. HENCE, TEMPERATURE CAN BE AN IMPORTANT INDICATOR IN THE ASSESSMENT OF THE METABOLIC STATE OF MITOCHONDRIA. CURRENT METHODS OF MONITORING MITOCHONDRIAL TEMPERATURE ARE SUBJECT TO ARTIFACTS THAT HAVE LED TO CONTROVERSIAL INTERPRETATIONS IN THE BIOMEDICAL COMMUNITY. THUS, A NOVEL MODALITY TO MONITOR MITOCHONDRIAL TEMPERATURE IS NEEDED. THIS PHASE I EFFORT WILL EXPLORE THE FEASIBILITY OF USING NITROGEN-VACANCY (NV) CENTERS IN NANODIAMONDS (NDNVS) IN COMBINATION WITH A HIGHLY SENSITIVE LOCK- IN CAMERA FOR WIDE FIELD OF VIEW MONITORING THE TEMPERATURE OF ISOLATED MITOCHONDRIA. NV CENTERS HAVE UNIQUE MAGNETO-OPTICAL PROPERTIES THAT CAUSE THEIR FLUORESCENCE OUTPUT TO BE ALTERED IN RESPONSE TO LOW POWER MICROWAVES AT SPECIFIC FREQUENCIES. THE SPECIFIC FREQUENCY IS RESPONSIVE TO TEMPERATURE ALLOWING THE NV CENTER SERVE AS A NANOSCALE SENSOR OF TEMPERATURE. AFTER DEMONSTRATING THE FEASIBILITY IN PHASE I, THE ULTIMATE GOAL IN PHASE II WILL BE THE DEVELOPMENT OF AN INSTRUMENT FOR IMAGING OF MITOCHONDRIAL TEMPERATURE AT A CELLULAR AND SUBCELLULAR LEVEL. THIS CAPABILITY CAN POTENTIALLY UNLOCK NEW MECHANISMS OF MITOCHONDRIAL FUNCTION IN CELLS AND THEIR BEHAVIOR UPON TREATMENT WITH SPECIFIC THERAPEUTIC AGENTS. THE PROPOSED EFFORTS COULD HAVE SIGNIFICANT TRANSLATIONAL IMPACT IN BOTH BASIC BIOLOGICAL RESEARCH AND DRUG DEVELOPMENT. THE TECHNICAL TEAM AT ADÁMAS HAS EXTENSIVE EXPERIENCE IN BOTH ND MATERIALS AS WELL AS INSTRUMENTATION FOR UTILIZING NDNV IN SENSING APPLICATIONS. THE TEAM WILL LEVERAGE ITS COMBINED EXPERIENCE WITH AN ULTIMATE GOAL OF PRODUCING A COMMERCIALLY VIABLE INSTRUMENT FOR BIO-COMMUNITY TO ASSESS MITOCHONDRIA (AND, MORE GENERALLY, CELLULAR) TEMPERATURE IN LIVE CELLS. THE PROJECT WILL ALSO INVOLVE INTENSIVE PROFESSIONAL DEVELOPMENT OF THE PRINCIPAL INVESTIGATOR (PI) AS PART OF THE ENTREPRENEURIAL DEVELOPMENT ASPECT OF THE PROPOSAL. THE PI WILL DEVELOP THE NECESSARY SKILLS TO TRANSITION FROM A BASIC SCIENTIST TO AN INDEPENDENT TECHNOLOGY COMMERCIALIZATION LEAD VIA INTENSIVE MENTORING PROVIDED AT ADÁMAS AND THE NIH I-CORPS PROGRAM. | $306.9K |
| R01GM143626↗ | Department of Health and Human Services | ADAMAS NANOTECHNOLOGIES, INC. | PROJECT GRANT (B) | 2026-05-04 | 2026-05-04 | 1 | PHOTO-HYPERPOLARIZED 13C MRI - SUMMARY. HIGH RESOLUTION IMAGING IN DEEP TISSUE (> 1 CM) ENVIRONMENTS CAN ADDRESS A SWATHE OF FUNDA- MENTAL AND APPLIED PROBLEMS IN THE ELUCIDATION OF MECHANISMS OF DISEASE ORIGIN AND PROGRESSION. WHILE FLUORES- CENCE IMAGING IS A WORKHORSE TECHNIQUE FOR THE CELLULAR IMAGING OF BIOLOGICAL MOLECULAR MARKERS, IT SUFFERS FROM LIGHT SCATTERING, AND ABERRATION DISTORTIONS AT TISSUE DEPTHS >1 MM. ON THE OPPOSITE END OF THE SPECTRUM, MAG- NETIC RESONANCE IMAGING (MRI) IS A WELL-ESTABLISHED AND BROADLY EMPLOYED PRE-CLINICAL AND CLINICAL IMAGING METHOD THAT HAS NO PRACTICAL LIMITATIONS WITH RESPECT TO TISSUE DEPTH, BUT IT SUFFERS FROM LOW RESOLUTION. IN THIS PROJECT WE WILL INNOVATE A NEW CLASS OF HYPERPOLARIZED 13C NANOPARTICLE PROBES THAT CAN SERVE AS EFFICIENT DEEP TISSUE MARKERS IN MRI. OUR CENTRAL IDEA IS TO DRAMATICALLY BOOST 13C NMR SIGNAL BY MEANS OF (I) OPTICAL HYPERPO- LARIZATION THAT CAN BE CARRIED OUT AT LOW MAGNETIC FIELDS AND (II) SIGNIFICANT EXTENSION OF 13C COHERENCE TIMES. SPECIFICALLY, WE PROPOSE TO DEVELOP MRI PROBES BASED ON FLUORESCENT NANODIAMONDS (FNDS) ENDOWED WITH NITROGEN-VACANCY (NV) CENTERS. THE ELECTRONIC SPINS ASSOCIATED WITH NVS CAN BE OPTICALLY “HYPERPOLARIZED” AND THAT POLARIZATION TO BE EFFECTIVELY TRANSFERRED TO THE DIAMOND 13C NUCLEAR SPINS, RESULTING IN NMR SIGNAL ENHANCE- MENT OVER THREE ORDERS OF MAGNITUDE VS. 13C THERMAL POLARIZATION AT THE FIELDS OF CLINICAL MRI. IN CONJUNCTION, BY IMPLEMENTING EFFECTIVE DECOUPLING SCHEMES WE PROPOSE SIGNIFICANTLY EXTEND THE 13C SPIN COHERENCES TO BE ABLE TO INTERROGATE THEM FOR SECOND-LONG PERIODS. THE LATTER YIELDS ENORMOUS SIGNAL GAINS, A MULTIPLICATIVE FACTOR OF ANOTHER 103- FOLD. COMBINING THE GAINS DUE TO HYPERPOLARIZATION AND SPIN COHERENCE EXTENSIONS PERMITS A TOTAL SIGNAL GAIN OF CA. 106 FOR MRI, AND WILL ENABLE A SIGNIFICANT IMPROVEMENT IN SPATIAL RESOLUTION. MOREOVER, SINCE THE POLARIZATION IS OPTICALLY GENERATED, THIS 13C PHOTO-MRI (PMRI), CAN BE CARRIED OUT AT LOW-FIELD AT A MUCH LOWER COST VS. CONVENTIONAL MRI INFRASTRUCTURE. IN OUR METHOD THE SPIN POLARIZATION IS REGENERATED OPTICALLY, ALLOWING FOR ACQUIRING MRI DATA REPEATEDLY AND ENABLING LONGITUDINAL STUDIES. FURTHERMORE, THE FND PARTICLES ARE INHERENTLY BIOCOMPATIBLE, AND THEIR SURFACES ARE AMENABLE TO A VERSATILE SET OF TARGETING LIGANDS. WITH THIS BASIS, WE PROPOSE TO DEVELOP TARGETABLE FLUORESCENT NANOPARTICLE MRI PROBES THAT CAN BE IMAGED WITH HIGH FIDELITY WITH RESOLUTION BETTER THAN 20 UM IN DEEP TISSUE (>1 CM) SETTINGS. IN ADDITION TO BEING BRIGHT MRI AGENTS, THE PARTICLES ARE ALSO BRIGHT FLUORESCENT PROVIDING AN OPTION FOR A CROSS-EXAMINATION OF THE AGENT BIODISTRIBUTION IN HISTOPATHOLOGICAL ANALYSIS. IN ORDER TO REALIZE THE PROSPECTS OF THIS NOVEL TECHNOLOGY, WE PROPOSE TO FURTHER DEVELOP THE HYPERPO- LARIZATION AND MR IMAGING METHODOLOGIES, AS WELL AS BOOST HYPERPOLARIZABILITY OF NANOSIZED PARTICLES BY OPTIMIZ- ING THEIR STRUCTURE THROUGH SYNTHESIS AND PROCESSING DEVELOPMENTS. WE AIM AT TRANSFERRING THE PMRI TECHNOLOGY WE DEMONSTRATED FOR MICRON-SIZED PARTICLES TO THE NANOSIZED FND SUITABLE FOR IN VIVO MRI. AS A PART OF THE TECHNOLOGY DEMONSTRATION, WE WILL CONSTRUCT A SIMPLE PROTOTYPE PMRI IMAGING SET-UP ON THE BENCHTOP (LOW-FIELD) AND IMAGE FNDS IN TISSUE PHANTOMS, CHARACTERIZING ACHIEVABLE METRICS OF RESOLUTION AND IMAGING DEPTH. | $0 |
| R44TR005336↗ | Department of Health and Human Services | ADAMAS NANOTECHNOLOGIES, INC. | PROJECT GRANT (B) | 2026-05-04 | 2026-05-04 | 1 | NANODIAMOND QUANTUM SENSORS FOR FREE RADICAL DETECTION - SUMMARY REACTIVE OXYGEN SPECIES (ROS) HAVE A UBIQUITOUS IMPACT ON HUMAN HEALTH. ROS ARE DIRECTLY INVOLVED IN MAINTENANCE OF HOMOEOSTASIS AND IMPLICATED IN DISEASE WHEN MISREGULATED. CURRENTLY THERE IS A GAP IN TECHNOLOGIES CAPABLE OF CHARACTERIZING AND QUANTIFYING THESE IMPORTANT ANALYTES IN PHYSIOLOGICALLY RELEVANT CONDITIONS (E.G., WHOLE BLOOD). THIS PHASE II SBIR CONTINUES DEVELOPMENT OF A QUANTUM SENSING TECHNOLOGY TO PERFORM ACCURATE AND ACCESSIBLE KINETIC MEASUREMENTS OF ROS IN MINIMALLY PROCESSED BIOFLUIDS. ONCE DEVELOPED, THE NEW TECHNOLOGY WILL IMPROVE THE UNDERSTANDING THE ROLES THESE SPECIES PLAY IN DISEASE PATHOGENESIS. IT IS ALSO EXPECTED TO ENABLE NEW MODALITIES FOR DRUG AND BIOMARKER DISCOVERY WHICH COULD POTENTIALLY AID IN CLINICAL DIAGNOSTICS. THE TRANSLATIONAL CAPABILITY OF QUANTUM SENSORS LIES IN EQUIPPING BIOMEDICAL RESEARCHERS AND CLINICIANS WITH NEW MEASUREMENT TOOLS OFFERING IMPROVED SENSITIVITY, RESOLUTION, AND SPEED COMPARED TO CLASSICAL SENSORS. THE PROPOSED NEW FAMILY OF ROBUST QUANTUM SENSORS IS BASED ON NITROGEN- VACANCY (NV) CENTERS FABRICATED IN NANODIAMONDS (NDS). NDNV SENSORS POSSESS UNIQUE MAGNETO-OPTICAL QUANTUM PROPERTIES, WHERE THE OPTICAL OUTPUT OF THE NV DEPENDS ON ITS SPIN STATE, WHILE THE SPIN STATE, IN TURN, IS HIGHLY SENSITIVE TO PARAMAGNETIC SPECIES/FREE RADICALS PRESENT NEARBY. THE VALUE OF THE PROPOSED TECHNOLOGY IS THAT THE MEASUREMENTS MAY BE REPRODUCIBLY PERFORMED IN A MEDIA WITH A HIGH BACKGROUND FLUORESCENCE, LIKE WHOLE BLOOD. TO ACHIEVE THIS GOAL, THIS PHASE II SBIR AIMS AT DEVELOPING A PROTOTYPE INSTRUMENT WHICH WILL BE FURTHER COMMERCIALIZED IN PHASE III OF THIS PROJECT. WE WILL ALSO CONTINUE DEVELOPMENT OF THE ND-NV SENSOR AND VALIDATION OF ITS PERFORMANCE WITH MEASUREMENTS IN TRANSLATIONALLY RELEVANT WHOLE BLOOD SAMPLES. OUR TEAM HAS COMPLEMENTARY EXPERTISE IN ND PROCESSING AND COMMERCIALIZATION AND INSTRUMENTATION PROTOTYPING (ADÁMAS), DEVELOPMENT OF CUTTING-EDGE DETECTION/VALIDATION SCHEMES IN ELECTRON PARAMAGNETIC RESONANCE (EPR) AND CHEMICAL SYNTHESIS (NCSU), AND CLINICAL RESEARCH (DUKE MEDICAL CENTER). THE OUTCOME OF THIS PROJECT WILL BE A SENSOR WITH THE CAPABILITY TO PERFORM MEASUREMENTS OF ROS IN WHOLE BLOOD WITH MINIMAL PROCESSING. WE ANTICIPATE THAT THE GREATLY REDUCED ASSAY TIME AND PRESERVED SAMPLE INTEGRITY WILL INCREASE THE RELIABILITY OF ROS MEASUREMENT IN BASIC BIOMEDICAL RESEARCH AND CLINICAL DIAGNOSTICS. WE AIM TO PROVIDE THE FULL TECHNOLOGY SOLUTION TO END USERS INCLUDING AN INSTRUMENT AND CONSUMABLE REAGENTS FOR CONDUCTING QUANTUM SENSING ROS ASSAYS. | $0 |