| UH3NS127063↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | COOPERATIVE AGREEMENT (B) | 2026-08-07 | 2026-08-07 | 2 | A NEUROMUSCULOSKELETAL INTERFACE FOR BIONIC ARMS: A RANDOMIZED CROSSOVER STUDY - LOSS OF AN ARM MAKES IT HARDER TO WORK, TO TAKE PART IN LEISURE ACTIVITIES, AND TO DO MANY OF THE TASKS NEEDED TO LEAD AN INDEPENDENT LIFE. USING AN ARTIFICIAL ARM (PROSTHESIS) CAN HELP WITH THESE ACTIVITIES, AND A LOT OF RESEARCH HAS GONE INTO DESIGNING ADVANCED PROSTHESES THAT CAN REPLACE THE MANY FUNCTIONS OF AN INTACT HAND AND ARM. HOWEVER, A PROSTHESIS IS TYPICALLY ATTACHED TO THE BODY USING A SOCKET, WHICH FITS OVER THE RESIDUAL LIMB. SOCKETS CAN CAUSE PROBLEMS WITH SKIN IRRITATION AND CAN BE UNCOMFORTABLE OR HOT TO WEAR FOR LONG PERIODS. ONE WAY AROUND THIS IS TO ATTACH THE PROSTHESIS DIRECTLY TO THE BONE OF THE RESIDUAL LIMB. THIS SOLVES THE PROBLEMS ASSOCIATED WITH WEARING A SOCKET, ALLOWS A WIDER RANGE OF MOVEMENT, AND THE MAKES THE PROSTHESIS FEEL MORE LIKE A PART OF THE USER’S BODY. THE PROSTHESIS IS ATTACHED TO A METAL ROD THAT IS INSERTED INTO THE ARM BONE DURING A TWO-STEP SURGERY. THE BONE THEN GROWS INTO THE METAL ROD, FORMING A STRONG PERMANENT ATTACHMENT. THIS PROCESS IS CALLED OSSEOINTEGRATION (OI). ANOTHER PROBLEM IS HOW TO CONTROL THE PROSTHESIS, I.E., HOW TO MAKE IT DO WHAT THE USER WANTS IT TO DO. SOME PROSTHESES ARE CONTROLLED USING SMALL ELECTRICAL SIGNALS (CALLED EMG SIGNALS) THAT ARE PRODUCED BY MUSCLES WHEN THEY CONTRACT. EMG SIGNALS ARE USUALLY RECORDED BY ELECTRODES PLACED ON THE SKIN OVER THE MUSCLE; THE SIGNALS ARE DECODED BY A COMPUTER ALGORITHM AND TURNED INTO CONTROL SIGNALS FOR THE PROSTHESIS. EMG SIGNALS RECORDED FROM THE SKIN SURFACE CAN BE UNRELIABLE, SO ANOTHER OPTION IS TO IMPLANT THE ELECTRODES ONTO THE MUSCLE. A SYSTEM CALLED OSSEOINTEGRATION OF PROSTHESES FOR THE REHABILITATION OF AMPUTEES (OPRA) USES OI TO ATTACH THE PROSTHESIS. A NEW VERSION OF THIS SYSTEM, E-OPRA, USES OI WITH IMPLANTED ELECTRODES. E-OPRA CAN ALSO BE USED TO STIMULATE PERIPHERAL NERVES SO THAT THE USER FEELS SOME SENSORY FEEDBACK FROM THE PROSTHESIS, WHICH ALSO MAY HELP WITH CONTROL OF THE DEVICE. OUR OBJECTIVE IS TO PERFORM TWO CLINICAL TRIALS TO FIRST TEST WHETHER E-OPRA PROVIDES BETTER FUNCTION AND COMFORT THAN OPRA, AND SECOND TO FIND OUT WHETHER E-OPRA IS BETTER WITH OR WITHOUT SENSORY FEEDBACK. OUR RATIONALE IS THAT DIRECTLY ATTACHING THE PROSTHESIS TO THE SKELETON HAS MANY ADVANTAGES OVER USE OF A SOCKET, THAT IMPLANTED ELECTRODES WILL PROVIDE CLEANER, MORE STABLE AND RELIABLE EMG SIGNALS THAN ELECTRODES AT THE SKIN SURFACE, AND THAT SENSORY FEEDBACK WILL HELP THE USER CONTROL THEIR DEVICE. WE THEREFORE EXPECT THAT THE E-OPRA SYSTEM WITH SENSORY FEEDBACK WILL PROVIDE IMPROVED PROSTHESIS CONTROL AND FUNCTION COMPARED TO CONVENTIONAL SOCKET-BASED SYSTEMS OR OI WITHOUT SENSORY FEEDBACK. | $2.17M |
| 90REGE0030↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | GRANT | 2026-08-26 | 2026-08-26 | 1 | BUILDING ADVANCED CEREBRAL PALSY ASSISTIVE CARE SOLUTIONS (BACPACS) - CEREBRAL PALSY (CP) IS THE MOST COMMON CAUSE OF PEDIATRIC DISABILITY IN THE UNITED STATES, AFFECTING 2-3 OF EVERY 1000 CHILDREN. THE GOAL OF OUR FIVE-YEAR RERC IS TO ENHANCE CLINICAL CARE FOR CHILDREN WITH CP BY MAXIMIZING THEIR MOBILITY AND QUALITY OF LIFE THROUGH A COMPREHENSIVE APPROACH EVALUATING THE EFFECTIVENESS OF ASSISTIVE AND THERAPEUTIC TECHNOLOGIES THAT TARGET MUSCLES, NERVES, AND BIOMECHANICS. OUR RERC HAS THREE PRIMARY OBJECTIVES: 1) DEVELOP ASSISTIVE DEVICES THAT ARE SPECIFICALLY DESIGNED FOR CHILDREN, 2) EVALUATE THE EFFECTIVENESS OF NOVEL INTERVENTIONS THAT TO PROMOTE LONG-TERM BENEFITS FOR CHILDREN WITH CP, AND 3) DEVELOP CLINICAL MONITORING AND PREDICTION SYSTEMS TAILORED TO CHILDREN WITH CP THAT CAN INFORM PERSONALIZED THERAPY. THE OUTCOMES OF THIS RERC WILL INCLUDE: 1) PARENTS AND CAREGIVERS HAVING MORE POTENTIAL THERAPEUTIC OPTIONS WHEN SEEKING TREATMENT FOR THEIR CHILDREN, 2) CLINICIANS GAINING ACCESS TO MONITORING AND PREDICTIVE CLINICAL TOOLS THAT CAN GUIDE THEIR DEVELOPMENT OF TREATMENT PLANS ON A MORE INDIVIDUALIZED BASIS, AND 3) CHILDREN WITH CP HAVING ACCESS TO NEW POWERED ASSISTIVE DEVICES THAT CAN BE MODIFIED TO GROW WITH THEM. THE PRODUCTS OF OUR RERC FOR CHILDREN WITH CP WILL BE 1) NOVEL THERAPEUTIC PARADIGMS FOR IMPROVING MOBILITY AND QUALITY OF LIFE, INCLUDING AT-HOME THERAPY DEVICES, NERVOUS SYSTEM STIMULATION, AND PHARMACOLOGICAL TREATMENT–R1, R2; 2) A MACHINE-LEARNING MODEL TO PREDICT A CHILD’S RESPONSIVENESS TO THERAPEUTIC INTERVENTIONS–R3; 3) AN AUTOMATED MONITORING SYSTEM TO EVALUATE THE EFFECTIVENESS OF TREATMENT ON GAIT–D1; AND 4) A POWERED, LOW-COST EXOSKELETON THAT CAN BE EASILY MODIFIED AS A CHILD GROWS TO CONTINUALLY ASSIST THEIR INDEPENDENT MOBILITY–D2. | $975.0K |
| 90DPHF0012↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | GRANT | 2026-08-31 | 2026-08-31 | 1 | INTERNATIONAL EXPLORATION OF REHABILITATION LENGTH OF STAY FOLLOWING SPINAL CORD INJURY - THE SHIRLEY RYAN ABILITYLAB IN PARTNERSHIP WITH INTERNATIONAL HEALTH AND REHABILITATION RESEARCHERS AND KEY STAKEHOLDERS WILL, IN THE COURSE OF THIS 5-YEAR PROJECT ESTABLISH INTERNATIONAL COLLABORATION FOCUSED ON HEALTH POLICY AND SCI OUTCOMES. THE GOAL OF THIS PROJECT IS TO GENERATE KNOWLEDGE ABOUT VARIATIONS IN REHABILITATION LOS AND INTENSITY AND HOW THESE VARIATIONS ARE ASSOCIATED WITH THE EXPERIENCE AND LONG-TERM OUTCOMES OF PEOPLE WITH SCI. THE OBJECTIVES ARE TO CONDUCT (A) A SYSTEMATIC REVIEW OF THE INTERNATIONAL RESEARCH LITERATURE ON ACUTE AND REHABILITATION LENGTHS OF STAY (LOS) AND INTENSITY FOLLOWING SCI, (B) COMPARATIVE INTERNATIONAL RESEARCH ON INTERNATIONAL VARIATIONS IN ACUTE CARE AND MEDICAL REHABILITATION LOS AND INTENSITY FOLLOWING SCI, AND (C) COMPARATIVE INTERNATIONAL RESEARCH ABOUT THE EXPERIENCES AND OUTCOMES OF PEOPLE WITH SCI AND COMPARE GROUPS WITH RELATIVELY SHORT VS LONG LOS. RESEARCH ACTIVITIES WILL INVOLVE PEOPLE WITH SCI AND OTHER KEY STAKEHOLDERS AND GENERATE CONTENT FOR KNOWLEDGE TRANSLATION ACTIVITIES. ANTICIPATED OUTCOMES ARE: (1) HEALTH POLICY MAKERS WILL HAVE A CONTEMPORARY EVIDENCE BASE TO INFORM POLICY OPTIONS, (2) REHABILITATION PROVIDERS WILL HAVE GUIDANCE ON STRATEGIES TO ENHANCE FUNCTIONAL OUTCOMES AND PATIENT EXPERIENCES, AND (3) PEOPLE WITH SCI AND THEIR CAREGIVERS WILL HAVE ACCESS TO INFORMATION TO GUIDE REHABILITATION CHOICES. THE EXPECTED PRODUCTS ARE RESEARCH PUBLICATIONS AND PRESENTATIONS, ADDITIONAL INSTRUMENT SUMMARIES IN THE REHABILITATION MEASURES DATABASE, AND ROBUST DISSEMINATION MATERIALS THAT TARGET KEY STAKEHOLDERS. | $840.0K |
| R35NS122336↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | PROJECT GRANT (B) | 2026-07-16 | 2026-08-27 | 2 | FROM NEURAL CONTROL OF MOVEMENT TO TREATMENTS FOR SPINAL CORD INJURY - PROJECT SUMMARY/ABSTRACT OVER THE LAST 15 YEARS, OUR NINDS-FUNDED RESEARCH HAS FOCUSED ON UNDERSTANDING TRANSMISSION IN DESCENDING MOTOR PATHWAYS AND SPINAL CORD NETWORKS DURING MOTOR BEHAVIORS IN HUMANS WITH AND WITHOUT SPINAL CORD INJURY (SCI), WITH THE LONG-TERM GOAL OF MAXIMIZING THE ACTIVITY OF SPARED PATHWAY CONNECTIONS TO ENHANCE RECOVERY POTENTIAL. OUR STUDIES REVEALED THAT IN PEOPLE WITH SCI, CORTICOSPINAL AND RETICULOSPINAL SYSTEMS CONTRIBUTE DIFFERENTIALLY TO MUSCLE WEAKNESS AND FUNCTIONALLY RELEVANT BEHAVIORS, SUCH AS FINE AND GROSS GRASPING MANIPULATIONS, COMPARED WITH CONTROL SUBJECTS. IMBALANCED CONTRIBUTIONS FROM THESE DESCENDING MOTOR SYSTEMS WERE FOUND WHEN SPASTICITY AND MUSCLE SPASMS WERE PRESENT, PROVIDING LIGHT FOR THE MECHANISMS OF HYPERREFLEXIA FOLLOWING SCI. MOTONEURON RESPONSIVENESS TO CORTICOSPINAL, RETICULOSPINAL, AND AFFERENT INPUT DECREASED IN A TASK- DEPENDENT MANNER. OUR RESEARCH GROUP PIONEERED THE USE OF SPIKE-TIMING DEPENDENT PLASTICITY IN THE CORTICOSPINAL PATHWAY, FROM BASIC PROOF-OF-PRINCIPLE STUDIES ON HEBBIAN PLASTICITY TO RANDOMIZED PLACEBO CONTROLLED CLINICAL TRIALS SHOWING THAT PLASTICITY AT CORTICOSPINAL-MOTONEURONAL SYNAPSES IMPROVES EXERCISE- MEDIATED RECOVERY AFTER CHRONIC INCOMPLETE SCI. IN THIS APPLICATION, WE REQUEST TO CONSOLIDATE TWO ONGOING NINDS-FUNDED PROPOSALS THAT FOCUS ON THE CONTROL OF VOLUNTARY MOVEMENT (R01NS090622) AND SPASTICITY AND MUSCLE SPASMS (R01NS100810). WE WILL LEVERAGE OUR EXISTING KNOWLEDGE TO PRODUCE NEW RESEARCH THAT CHALLENGES THE EXISTING PARADIGM BY INTEGRATING INFORMATION ACROSS RESIDUAL NETWORKS IN THE SUBACUTE AND CHRONIC PHASES OF SCI AND FOCUSES ON UNDERSTANDING: A) TRANSMISSION IN A WIDESPREAD SET OF SPARED DESCENDING MOTOR PATHWAYS AND SPINAL CIRCUITS, B) HYPERREFLEXIA IN THESE SPARED SYSTEMS, AND C) NEUROPLASTICITY-BASED THERAPIES. OUR RESEARCH PROTOCOL WILL BUILD ON OUR PAST SUCCESSES USING CUTTING-EDGE NEUROPHYSIOLOGICAL, NEUROIMAGING, AND BEHAVIORAL TOOLS. WE WILL EMPLOY MORE ADVANCED SPINAL CORD IMAGING METHODOLOGIES, HIGH-DENSITY SURFACE ELECTROMYOGRAPHY RECORDINGS, AND NEW PHYSIOLOGICAL EXAMINATIONS USING MULTIDIMENSIONAL BEHAVIORAL TOOLS TO ENHANCE OUR UNDERSTANDING OF RESIDUAL CONNECTIONS IN HUMANS WITH SUBACUTE AND CHRONIC SCI. SUCCESSFUL COMPLETION OF THIS RESEARCH WILL INCREASE OUR UNDERSTANDING OF THE NEURAL CONTROL OF MOVEMENT AND SYMPTOMS, INCLUDING SPASTICITY AND MUSCLE SPASMS, IN OTHER NEUROLOGICAL DISORDERS (I.E., STROKE, MULTIPLE SCLEROSIS, AND ALS). THIS RESEARCH ALSO MAY PROVIDE NEW AVENUES FOR TREATMENTS AND ASSESSMENT OF HUMANS WITH SCI AND OTHER NEUROLOGICAL DISORDERS. | $767.7K |
| R01HD117997↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | PROJECT GRANT (B) | 2026-07-07 | 2026-07-07 | 1 | EARLY DETECTION AND SURVEILLANCE OF INFANT MOTOR DEFICITS: A WEARABLE SENSOR TOOLKIT FOR AUTOMATED HOME EVALUATIONS - PROJECT SUMMARY/ABSTRACT MORE THAN 17% OF INFANTS BORN IN THE UNITED STATES HAVE MOTOR DEFICITS WHICH RESTRICT THEIR DEVELOPMENT, DAILY FUNCTION, AND QUALITY OF LIFE. EARLY INTERVENTION CAN IMPROVE OUTCOMES FOR THESE INFANTS BY EFFECTIVELY RETRAINING THE BRAIN AND BODY DURING A CRITICAL PERIOD OF DEVELOPMENT. HOWEVER, MOTOR DEFICITS ARE OFTEN NOT DETECTED UNTIL 1-2 YEARS OF AGE OR LATER, WHICH CAN REDUCE THE EFFICACY OF INTERVENTIONS DUE TO LATE INITIATION AND LOWERED BRAIN PLASTICITY. CURRENT EVALUATION METHODS, SUCH AS CAREGIVER REPORTS AND OBSERVATION-BASED CLINICAL ASSESSMENTS, LACK THE ACCESSIBILITY, OBJECTIVITY, AND PRECISION NEEDED TO EVALUATE EARLY INFANT MOVEMENT OUTSIDE OF A CLINICAL SETTING AND SCREEN FOR ATYPICAL MOTOR BEHAVIORS. THE OBJECTIVE OF THE PROPOSED STUDY IS TO DEVELOP A FULLY AUTOMATED WEARABLE SENSOR TOOLKIT TO DETECT INFANT MOTOR DEFICITS WITHIN THE FIRST FEW MONTHS OF LIFE DURING FREE- LIVING ACTIVITIES THE HOME AND COMMUNITY, AND TO SURVEIL THESE DEFICITS OVER THE FIRST YEAR OF LIFE. CAPTURING FREE- LIVING INFANT MOVEMENTS WOULD PROVIDE A MORE COMPREHENSIVE AND REPRESENTATIVE PICTURE OF EVERYDAY INFANT BEHAVIOR COMPARED TO CURRENT EVALUATION METHODS. WE WILL DEVELOP THE WEARABLE SENSOR TOOLKIT VIA THE FOLLOWING AIMS. IN AIM 1, WHOLE-BODY INERTIAL SENSOR DATA WILL BE RECORDED IN THE HOME AND COMMUNITY FROM UP TO 60 NEWBORN INFANTS ACROSS THE RISK SPECTRUM FOR MOTOR DEFICITS TO CURATE A PEDIATRIC DATASET OF REAL-WORLD, EARLY MOTOR DEVELOPMENT. IN AIM 2, THIS DATASET WILL BE USED ALONG WITH STATE-OF-THE-ART SIGNAL PROCESSING AND MACHINE LEARNING TECHNIQUES TO DEVELOP A TOOLKIT THAT COLLECTS AND AUTOMATICALLY ANALYZES WEARABLE SENSOR DATA TO EVALUATE MOTOR DEVELOPMENT FOR INFANTS LESS THAN 3 MONTHS OF AGE DURING EVERYDAY ACTIVITIES AND INFANT BEHAVIORS IN THE HOME AND COMMUNITY. FINALLY, IN AIM 3, THE TOOLKIT WILL BE VALIDATED IN A SEPARATE COHORT OF 30 NEWBORN INFANTS TO EVALUATE ITS EFFECTIVENESS IN DETECTING AND DESCRIBING INFANT MOTOR DEFICITS OVER THE FIRST YEAR OF LIFE COMPARED TO TRADITIONAL CLINICAL ASSESSMENTS. THE PRIMARY OUTCOMES WILL BE A FULLY ANNOTATED, FREE-LIVING DATASET CHARACTERIZING INFANT MOTOR DEVELOPMENT BETWEEN BIRTH AND 3 MONTHS OF AGE, AS WELL AS THE SENSITIVITY AND SPECIFICITY OF THE WEARABLE SENSOR TOOLKIT TO DETECT INFANT MOTOR DEFICITS DURING THESE EARLY AGES. SECONDARY OUTCOMES WILL INCLUDE SURVEILLANCE CURVES OF SENSOR-BASED METRICS TO TRACK MOTOR DEVELOPMENT OVER THE FIRST YEAR OF LIFE, AND CLINICAL OUTCOMES OF INFANTS TRACKED AND NOT TRACKED BY THE TOOLKIT. THIS STUDY WILL REVOLUTIONIZE DETECTION AND SURVEILLANCE OF INFANT MOTOR DEVELOPMENT AND DEFICITS BY AUTOMATICALLY EVALUATING EARLY-LIFE MOVEMENT PATTERNS IN THE HOME AND COMMUNITY, ALERTING CLINICIANS AND CAREGIVERS WHEN FURTHER EXAMINATION IS NEEDED. EARLY, ACCURATE, AND ACCESSIBLE METHODS OF IDENTIFYING INFANT MOTOR DEFICITS WOULD ALLOW FOR MORE WIDESPREAD DEVELOPMENTAL SCREENING AND EARLIER, TARGETED INTERVENTIONS TO IMPROVE LIFELONG OUTCOMES. | $720.5K |
| R01HD121729↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | PROJECT GRANT (B) | 2026-05-27 | 2026-05-27 | 1 | RETHINKING SYMMETRY: A NEW FRAMEWORK FOR POWERED KNEE PROSTHESES - PROJECT SUMMARY MILLIONS OF INDIVIDUALS AROUND THE WORLD ARE AFFECTED BY TRANSFEMORAL LOWER LIMB LOSS, REDUCING THEIR MOBILITY AND PROFOUNDLY IMPACTING THEIR QUALITY OF LIFE. REDUCED MOBILITY IS A MAJOR CONTRIBUTOR TO ADVERSE PHYSICAL AND MENTAL HEALTH OUTCOMES, INCLUDING LIMITED SOCIAL PARTICIPATION, INABILITY TO RETURN TO WORK, AND INCREASED DEPRESSION. RESTORING THE MAXIMUM POSSIBLE MOBILITY IS, THUS, A CRITICAL CONCERN. PROSTHETIC DEVICES ARE ACCEPTED TREATMENT OPTIONS FOR LOWER LIMB AMPUTATION, BUT EVEN ADVANCED PROSTHESES LIKE MICROPROCESSOR-CONTROLLED KNEES (MPKS) FALL SHORT OF RESTORING PRE-AMPUTATION GAIT FUNCTION. POWERED PROSTHETIC KNEES OFFER THE POTENTIAL TO RESTORE JOINT TORQUE AND REPLICATE HUMAN LIMB FUNCTIONS. HOWEVER, THEIR INCREASED MASS AND INERTIA OFTEN DIMINISH THEIR BENEFITS AND LIMIT USER ADOPTION. WHILE REDUCING THE MASS OF A POWERED PROSTHESIS HAS A PRACTICAL LIMIT, A MORE STRAIGHTFORWARD AND TRACTABLE APPROACH TO OVERCOME THESE LIMITATIONS IS TO REDUCE THE INERTIA OF THE DEVICE BY PLACING THE POWERTRAIN ABOVE THE KNEE INSTEAD OF BELOW IT, CONCENTRATING THE MASS MORE PROXIMAL TO THE TRUNK. THIS REDISTRIBUTES, RATHER THAN REDUCES, THE MASS TO IMPROVE GAIT. WHILE STUDIES OF HAVE SHOWN THAT ABOVE-KNEE MASS PLACEMENT IS SUPERIOR TO BELOW-KNEE MASS PLACEMENT IN PASSIVE PROSTHETIC KNEES, THE BUILD HEIGHT OF CURRENT POWERED DEVICES HAS PREVENTED DIRECT TESTING OF THIS APPROACH. SPECIFICALLY, MOVING THE POWERTRAIN ABOVE THE KNEE WOULD NECESSITATE MOVING THE PROSTHETIC KNEE CENTER SUBSTANTIALLY BELOW THE SOUND KNEE, INTRODUCING A LARGE DEGREE OF ASYMMETRY. ALTHOUGH A MODERATE AMOUNT OF KNEE HEIGHT ASYMMETRY HAS BEEN SHOWN TO ACTUALLY IMPROVE STEP TIME SYMMETRY WHEN USING A PASSIVE PROSTHESIS, THE DISPARITY IN KNEE HEIGHT REQUIRED FOR POWERTRAIN REPOSITIONING IN CURRENT DEVICES WOULD LIKELY HAVE ADVERSE IMPACTS ON GAIT. HOWEVER, OUR NEW LOW-PROFILE POWERED KNEE PROTOTYPE HAS A SMALL BUILD HEIGHT THAT MAKES POWERTRAIN REPOSITIONING POSSIBLE. THE PROPOSED STUDY SEEKS TO GAIN FUNDAMENTAL BIOMECHANICAL INSIGHTS ON HOW MASS PLACEMENT, KNEE HEIGHT, AND POWERED ASSISTANCE INTERACT TO AFFECT GAIT. IN AIM 1, WE WILL UTILIZE PREDICTIVE SIMULATION AND BIOMECHANICAL MODELING TECHNOLOGY TO PERFORM IN SILICO TESTING OF VARIOUS KNEE HEIGHT AND MASS PLACEMENT CONFIGURATIONS OF A PROSTHESIS ON VIRTUAL SUBJECTS WITH DIFFERING PHYSICAL CHARACTERISTICS, SUCH AS RESIDUAL LIMB LENGTH. THIS ALLOWS OUR TEAM TO TEST A WIDE ARRAY OF CONFIGURATIONS IN A RAPID AND EFFICIENT MANNER. IN AIM 2, WE WILL PERFORM HUMAN SUBJECTS TESTING TO ASSESS HOW KNEE HEIGHT ASYMMETRY AND MASS PLACEMENT AFFECT GAIT WHEN USING A PASSIVE PROSTHETIC KNEE. FINALLY, IN AIM 3, WE WILL ASSESS HOW THE PLACEMENT OF THE POWERTRAIN, WHICH ACCOUNTS FOR MOST OF THE MASS AND INFLUENCES KNEE JOINT HEIGHT IN OUR LOW-PROFILE POWERED KNEE PROTOTYPE, AFFECTS WALKING PERFORMANCE IN LOWER LIMB PROSTHESIS USERS. THIS WORK LEVERAGES OUR NEW DEVICE TO SYSTEMATICALLY INVESTIGATE HOW MASS PLACEMENT, KNEE HEIGHT ASYMMETRY, AND POWERED ASSISTANCE INTERACT TO AFFECT MOBILITY. UNLIKE PRIOR STUDIES, WHICH EXAMINE THESE FACTORS IN ISOLATION AND ONLY IN PASSIVE KNEES, OUR WORK WILL GENERATE FOUNDATIONAL DATA NEEDED TO INFORM EVIDENCE-BASED DESIGN OF NEXT-GENERATION POWERED PROSTHESES TO OPTIMIZE OUTCOMES. | $711.2K |
| R01AG094904↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | PROJECT GRANT (B) | 2026-07-23 | 2026-07-23 | 1 | AIRBAGS TO PREVENT HIP INJURIES IN THE AGING STROKE POPULATION - PROJECT SUMMARY/ABSTRACT OVER 95% OF THE 300,000 HIP FRACTURES THAT OCCUR ANNUALLY IN THE US ARE CAUSED BY FALLS, AND 27% OF OLDER ADULTS WITH HIP FRACTURE DIE DUE TO COMPLICATIONS WITHIN A YEAR. MOREOVER, UP TO 70% OF OLDER ADULTS WITH A HISTORY OF STROKE EXPERIENCE MULTIPLE FALLS EVERY YEAR, RESULTING IN SIGNIFICANT INJURIES AND A HIGH MORTALITY RATE. IN THE STROKE POPULATION, OVER HALF OF ALL FALL-RELATED BONE FRACTURES OCCUR AT THE HIP. RESEARCH AIMING TO ADDRESS THIS ISSUE HAS LARGELY FOCUSED ON FALL PREVENTION STRATEGIES, BUT DUE TO DIFFERENT FALL PATTERNS AND VARIOUS RISK FACTORS THAT RESULT FROM STROKE, THESE STRATEGIES HAVE LITTLE TO NO EFFECT FOR OLDER ADULTS WITH A STROKE, WHO CONTINUE TO FALL REPEATEDLY AND ARE OFTEN LEFT WITH SEVERE LONG-TERM DISABILITIES. THIS PROJECT OFFERS AN ALTERNATIVE: STROKE-SPECIFIC FALL IMPACT MITIGATION USING WEARABLE AIRBAGS IN THE COMMUNITY. WEARABLE AIRBAGS DEPEND ON PRE-IMPACT FALL DETECTION ALGORITHMS TO DETECT FALLS AS THEY OCCUR TO DEPLOY AIRBAGS AND MITIGATE THE IMPACT, BUT ALGORITHMS DEVELOPED FOR NON-NEUROLOGICALLY IMPAIRED INDIVIDUALS (CALLED GENERALIZED ALGORITHMS) ARE LESS ACCURATE FOR PEOPLE WITH A HISTORY OF STROKE, PROMPTING OUR PRIOR DEVELOPMENT OF A STROKE-SPECIFIC FALL DETECTION ALGORITHM. THE OBJECTIVE OF THIS PROPOSAL IS TO EVALUATE THE EFFECTIVENESS OF A WEARABLE HIP AIRBAG EMBEDDED WITH OUR STROKE-SPECIFIC PRE-IMPACT FALL DETECTION ALGORITHM TO ACCURATELY DEPLOY AIRBAGS DURING FALLS, REDUCE HIP INJURIES, DECREASE FEAR OF FALLING, AND INCREASE COMMUNITY AMBULATION IN OLDER ADULTS WITH STROKE. IN AIM 1, 44 OLDER ADULTS AGED 65-90 WITH A HISTORY OF STROKE AND FALLS WILL BE RECRUITED IN A COMMUNITY-BASED CROSSOVER TRIAL. AIM 1 WILL BE DIVIDED INTO TWO SUB-AIMS: AIM 1A WILL COMPARE THE PERFORMANCE RATES OF THE STROKE-SPECIFIC AND GENERALIZED FALL DETECTION ALGORITHMS IN DETECTING REAL-WORLD FALLS IN THE COMMUNITY AND DEPLOYING AIRBAGS, WHILE AIM 1B WILL COMPARE THE RATES OF INJURY, FEAR OF FALLING AND COMMUNITY ENGAGEMENT DURING THE USE OF THE AIRBAG DEVICE WITH EACH EMBEDDED FALL DETECTION ALGORITHM. AIM 2 WILL DEVELOP A CLINICAL TOOL THAT USES THE BASELINE CLINICAL DATA TO IDENTIFY AND PREDICT RESPONDERS TO EACH ALGORITHM, HELPING US TO PREDICT WHICH ALGORITHM PROVIDES THE MOST BENEFIT FOR SPECIFIC INDIVIDUALS WITH STROKE. THE PRIMARY OUTCOMES WILL BE THE F1 SCORE (A METRIC THAT ACCOUNTS FOR PRECISION AND SENSITIVITY) OF THE STROKE-SPECIFIC ALGORITHM COMPARED TO THE GENERALIZED ALGORITHM (AIM 1), AND THE ACCURACY OF THE CLINICAL TOOL FOR PREDICTING RESPONDERS (AIM 2). SECONDARY OUTCOMES INCLUDE THE RATES OF FALL INJURY, FEAR OF FALLING, COMMUNITY AMBULATION, IMPRESSION OF THE DEVICE, AND QUALITY OF LIFE. THIS WORK WILL (I) DETERMINE THE PERFORMANCE RATES OF THE STROKE-SPECIFIC ALGORITHM COMPARED TO THE GENERALIZED ALGORITHM FOR AIRBAG DEPLOYMENT DURING A FALL IN OLDER ADULTS WITH STROKE HISTORY IN THE COMMUNITY, (II) EVALUATE THE BENEFITS OF A STROKE-SPECIFIC AIRBAG SYSTEM IN REDUCING HIP INJURIES AND FEAR OF FALLING, AND INCREASING COMMUNITY ENGAGEMENT, AND (III) DEVELOP A CLINICAL TOOL TO UTILIZE A SINGLE VISIT’S WORTH OF CLINICAL DATA TO PREDICT RESPONSIVENESS TO THE STROKE-SPECIFIC OR GENERALIZED FALL DETECTION ALGORITHMS AND GUIDE FUTURE PRESCRIPTION. THESE RESULTS WILL LAY THE GROUNDWORK FOR CONDITION-SPECIFIC FALL PROTECTION FOR OTHER HIGH-RISK POPULATIONS, AND SYSTEMS TO PROTECT AGAINST OTHER INJURIES, LIKE HEAD IMPACTS. | $691.8K |
| R01HD108554↗ | Department of Health and Human Services | REHABILITATION INSTITUTE OF CHICAGO | PROJECT GRANT (B) | 2026-06-01 | 2026-06-01 | 1 | UNDERSTANDING HOW POWERED COMPONENTRY IMPACTS K2-LEVEL TRANSFEMORAL AMPUTEE GAIT - PROJECT SUMMARY POWERED PROSTHETIC KNEE AND ANKLE JOINTS CAN ACTIVELY GENERATE TORQUE, POTENTIALLY ENABLING SAFE AND EFFICIENT PERFORMANCE OF MORE DEMANDING MOBILITY TASKS, SUCH AS ASCENDING RAMPS AND STAIRS OR PERFORMING SIT-TO-STAND TRANSITIONS, AND IMPROVING ENERGY EFFICIENCY. HOWEVER, AVAILABLE POWERED COMPONENTS HAVE BEEN ALMOST EXCLUSIVELY DEVELOPED FOR AND TESTED BY INDIVIDUALS AMBULATING AT MEDICARE FUNCTIONAL CLASSIFICATION LEVEL (MFCL) K3-OR K4. INDIVIDUALS DESIGNATED AS K2-LEVEL AMBULATORS (I.E., HAVE A MORE LIMITED AMBULATION CAPACITY) ARE TYPICALLY PRESCRIBED A PASSIVE PROSTHESIS, BUT THESE INDIVIDUALS HAVE BEEN SHOWN TO BENEFIT FROM MORE ADVANCED MICROPROCESSOR-CONTROLLED KNEES AND MAY GAIN ADDITIONAL BENEFIT FROM POWERED COMPONENTS. BECAUSE AVAILABLE POWERED COMPONENTS ARE HEAVY, WE DEVELOPED LIGHTWEIGHT, FULLY POWERED KNEE AND ANKLE COMPONENTS THAT CAN BE USED SEPARATELY OR TOGETHER AND ARE APPROPRIATE FOR K2-LEVEL AMBULATORS. THESE DEVICES WILL ALLOW US TO EVALUATE THE BENEFITS ASSOCIATED WITH PROVIDING POWER AT THE KNEE, ANKLE, OR KNEE AND ANKLE, AND THE TRADEOFFS ASSOCIATED WITH THE ADDITIONAL WEIGHT AND CONTROL COMPLEXITY OF ONE OR MORE POWERED COMPONENTS. OUR GOAL IS TO DETERMINE HOW POWERED PROSTHETIC COMPONENTS EFFECT FUNCTION—IN TERMS OF METABOLIC COST, GAIT BIOMECHANICS, AND FUNCTIONAL MOBILITY IN K2-LEVEL AMBULATORS WITH A UNILATERAL TRANSFEMORAL AMPUTATION, WHO USE A PRESCRIBED PASSIVE PROSTHESIS. WE WILL RECRUIT 20 INDIVIDUALS, WHO WILL PARTICIPATE IN THREE AIMS, WITH THE EXPECTATION THAT 15 WILL COMPLETE THE STUDY. FOR AIM 1, SUBJECTS WILL BE FIT FIRST WITH A FULLY PASSIVE DEVICE (OTTOBOCK C-LEG 4 MPK AND A TRITON 1C60 FOOT) AND THEN TO OUR FULLY POWERED DEVICE (KNEE-+ ANKLE PROSTHESIS). THEY WILL BE TRAINED TO USE EACH DEVICE BEFORE COMPLETING THE AMPUTEE MOBILITY PREDICTOR WITH PROSTHESIS (AMPPRO) (PRIMARY OUTCOME) AS WELL AS METABOLIC AND BIOMECHANICAL ASSESSMENTS, A SET OF STANDARD OUTCOME MEASURES, AND SELF-REPORT SURVEYS (SECONDARY OUTCOMES). FOR AIM 2, WE WILL EVALUATE COMBINATIONS OF POWERED KNEE + PASSIVE ANKLE AND PASSIVE KNEE + POWERED ANKLE, IN RANDOM ORDER. SUBJECTS WILL BE TRAINED TO USE EACH DEVICE, AND THE SAME PRIMARY AND SECONDARY OUTCOME MEASURES WILL BE PERFORMED TO ASSESS FUNCTIONAL BENEFITS AND THE EFFECTS OF ADDITIONAL WEIGHT AT THE KNEE OR ANKLE. IN AIM 3, WE WILL PROVIDE INTENSIVE TRAINING TO ENABLE SUBJECTS TO INDEPENDENTLY PERFORM TYPICAL ACTIVITIES OF DAILY LIVING AND ACHIEVE PERSONAL MOBILITY GOALS USING THE POWERED KNEE + ANKLE DEVICE, TO DETERMINE WHAT LEVEL OF IMPROVEMENT K2- LEVEL AMBULATORS CAN ATTAIN. SUBJECTS WILL AGAIN COMPLETE THE SAME PRIMARY AND SECONDARY OUTCOME MEASURES USING THE POWERED DEVICE AND WILL REPEAT THESE MEASURES USING THE PASSIVE DEVICE FROM AIM 1, TO ACCOMMODATE CARRYOVER OF TRAINING EFFECTS FROM PREVIOUS AIMS. THE ANTICIPATED OUTCOME IS AN UNDERSTANDING OF HOW POWER AND THE WEIGHT OF PROSTHETIC COMPONENTS AFFECT FUNCTION IN K2-LEVEL AMBULATORS, WHICH WILL ENABLE OPTIMAL SELECTION OF COMPONENTS TO IMPROVE FUNCTIONAL MOBILITY IN INDIVIDUALS WHO ARE DESIGNATED AS LIMITED COMMUNITY AMBULATORS AND CURRENTLY RESTRICTED TO PASSIVE DEVICES. | $674.7K |